SX70 Wood Stains
Boracol
Damp Proof Membrane
Damp Proof Cream
Tanking Slurry Systems
Explore Newton
Shop Wykamol Membranes
Waterproof Membrane Kits
ISO-THERM Insulation
Nuaire PIV units
Crack Sealing
Crack Stitching Bars
Explore Soudal
Fix ALL Rewards!
'Genius Gun' Foam Range
Special Offers
Wonder Grip Hub
Harris Brushes
Protection Films
Browse All Deals
How To Damp Proof Walls
Woodworm: Ultimate Guide
How To Stop Condensation
How To Seal Window Frames
The Nuaire Drimaster ECO-NOX-HC (Code DRI-ECO-NOX-HC) is a loft-mounted, hall-control Positive Input Ventilation (PIV) unit designed specifically for homes affected by traffic-related pollution. It combines a high-capacity PIV fan with twin stages of filtration at each inlet: ePM10 particulate filters alongside dedicated carbon cartridges that target nitrogen oxides (NOx).
Independently BRE-tested, the system reduces hazardous NOx entering the dwelling by up to 80% while tackling condensation, damp and black mould associated with poor ventilation. Controls and indicators are located on the ceiling diffuser for simple commissioning and maintenance prompts.
Ultra-low running power (typically 1.6–15.3W), Building Regulations Parts F & L compliance and a 7-year warranty (1-year parts & labour, remaining 6 years parts) complete a robust, low-maintenance solution for urban air quality and moisture control.
Unit
Free Delivery
on orders over £100(ex. VAT, mainland UK only)
Free Help & Advice
Call 01355 222 777Mon.-Fri 8:30am - 4:15pm, or email us
Next Day Delivery
Order Before 2:30pm for Same Day Despatch (terms apply)
Great Service
A proudly independent family business with 40 years experience
✔️ Dual-stage filtration with ePM10 prefilters and activated carbon cartridges reduces NOx ingress by up to 80%.
✔️ Positive Input Ventilation dilutes humidity and odours, tackling surface condensation and black mould across the home.
✔️ Hall Control diffuser interface selects higher airflow steps for NOx models, delivering around 18–41 litres per second.
✔️ Temperature-smart logic boosts to harvest loft warmth and pauses in excessive heat, maintaining comfort and efficiency.
✔️ Low running power 1.6–15.3W, BBA approved and seven-year warranty for assured, economical whole-house ventilation.
The Nuaire Drimaster ECO-NOX-HC is engineered for homes where outdoor air quality is a concern, including properties near busy roads and within Air Quality Management Areas. Working on the Positive Input Ventilation principle, the unit introduces tempered, filtered air from the loft at a gentle, continuous rate via a discreet ceiling diffuser. As this background supply dilutes and displaces moist, stale indoor air, it helps to control surface condensation on cold bridges and window reveals, reducing the damp conditions that enable black mould to develop and supporting a fresher living environment.
What distinguishes the ECO-NOX-HC is its two-stage filtration. Each inlet carries an ePM10 particulate filter to capture coarse particles such as dust and pollen, while an integrated carbon cartridge pack adsorbs traffic-related pollutants including nitrogen dioxide. Independent BRE testing has demonstrated up to 80% reduction of NOx ingress with this configuration, delivering a measurable improvement in indoor air quality for occupants.
Control and commissioning are carried out at the diffuser inside the home, hence Hall Control. The display allows airflow selection to suit the dwelling and offers temperature response profiles. When loft air is beneficially warmer, the unit can increase airflow to harvest free heat under Heat Recovery modes. In very hot loft conditions it will enter standby to maintain comfort. Because the carbon media increases resistance, ECO-NOX-HC operates on the higher speed steps of the Drimaster range, typically steps 3 to 6, providing supply rates of approximately 18 to 41 litres per second depending on the setting and property needs.
Despite the additional filtration, the motor remains highly efficient. Typical electrical demand ranges from about 1.6 to 15.3 watts depending on the selected speed, which helps to keep whole-home background ventilation economical while maintaining effective dilution of moisture, odours and pollutants.
Maintenance is simple and clearly signposted. The diffuser shows a filter-change reminder with a “C” after the recommended interval. Nuaire advises a visual check of the ePM10 filters every two years and replacement at least every five years, while the carbon cartridges should be renewed every two years to preserve NOx performance. Consumables are supplied as a matched kit for the NOX models to ensure the correct combination is fitted each time. The unit meets Building Regulations Parts F and L and holds BBA Agrément approval under the Drimaster ECO loft-mounted PIV certification. A seven-year warranty, comprising one year parts and labour followed by six years parts only in the UK and Ireland, provides long-term assurance.
NOx Filtration For Urban Homes: Twin carbon cartridges at each air inlet work alongside ePM10 particulate filters to significantly cut traffic-related pollutants (including NO₂), helping protect health and comfort in properties near busy roads. BRE testing reports up to 80% NOx reduction at the point of entry.
Proven Positive Input Ventilation: Constant, gentle supply air dilutes indoor humidity and pollutants, displacing them to outside and interrupting the condensation–damp–mould cycle that damages décor and wellbeing.
Hall-Control Convenience: All everyday commissioning and checks are done at the ceiling diffuser within the dwelling: set airflow, select temperature response, and view maintenance prompts without accessing the loft.
Energy-Efficient Operation: EC motor technology delivers whole-home airflow for very low power draw (about 1.6–15.3W typical), helping keep running costs modest while maintaining continuous background ventilation.
Intelligent Temperature Response: Selectable operating modes allow “heat recovery” behaviour when the loft is warmer than the home, and automatic standby in very hot lofts to protect comfort and efficiency.
Low-Touch Maintenance: The diffuser’s “C” reminder indicates when service is due. Guidance is simple: change carbon filters every 2 years; check ePM10 filters every 2 years and replace at least every 5 years. Kits are readily available to simplify upkeep.
Compliance And Assurance: Designed to meet Building Regulations Parts F & L for ventilation and energy, and covered within BBA Agrément certification for the Drimaster-ECO loft-mounted PIV range.
Seven-Year Warranty: Supported by a 7-year warranty (1-year parts & labour, remaining 6 years parts) for long-term confidence.
Urban And Roadside Properties: Homes close to main roads, junctions and bus routes where outdoor NOx is elevated; the carbon+ePM10 filtration strategy reduces ingress while the PIV principle improves overall IAQ.
Condensation And Mould Remediation: Dwellings suffering from recurring window condensation, musty odours and black mould on cold surfaces benefit from continuous, gentle air change that lowers humidity.
Refurbishment And Retrofit: Quick to install in existing lofts with minimal disruption; commissioning at the diffuser avoids repeated loft access and suits occupied homes.
Family Homes And Allergy Sensitivity: ePM10 filtration helps capture coarse particulates such as dust and pollen; continuous supply improves perceived freshness and reduces indoor pollutant build-up from cooking and cleaning.
Work only when you have safe loft access, good lighting and secure boarding. Never step on unboarded plasterboard ceilings. Wear gloves, eye protection and a dust mask because loft dust can be irritant, and handle the carbon media with care; wash hands after contact. Isolate the unit at its local isolator or the consumer unit and treat all wiring as live until confirmed otherwise. Ensure any open-flued appliances have sound flues and that existing extract fans discharge to outside. Incorporate a suitable means of all-pole disconnection in the fixed wiring and follow current wiring regulations.
Choose the diffuser position in the central hallway (single storey) or on the ceiling of the top-floor landing (two or more storeys) so supply air can flow along the ceiling and then cascade through the dwelling.
Respect the manufacturer’s minimum clearances from the nearest wall, which vary by the selected speed (from 100mm at the lowest setting up to 1000mm at the highest), and keep at least 1m away from a smoke alarm. If you cannot relocate the diffuser, use the supplied air dams to close two sides so discharge is directed across at least 1.5m of unobstructed ceiling away from the alarm.
In the loft, confirm there is general ventilation, that water tanks are lidded, pipes are lagged, the loft hatch seals well and that ceiling penetrations are sealed. Plan a short, direct route for the flexible duct (maximum recommended length 2m) and identify a sound timber from which to suspend the fan (or a joist line if you prefer anti-vibration mounting).
This model is supplied with hall controls at the diffuser for commissioning from inside the property. Keep the duct run under 2m with smooth bends and airtight joints; do not compress the duct as this reduces performance.
The unit can be suspended from a roof timber using the supplied cord, or mounted to joists using the optional anti-vibration kit (code 771393). Provide a local isolator and connect the pre-wired power supply via a fused spur to a 230V supply; a qualified electrician must complete this work.
If the dwelling is three storeys, fit a smoke/CO alarm shutdown link using compatible alarms with relay bases so the unit stops automatically on alarm; this interlock is a mandatory requirement for three-storey installations.
Make The Area Safe And Gather Parts: Isolate the supply, lay secure loft boarding so you can reach the work area comfortably, and bring the fan unit, ceiling diffuser, flexible duct, cable ties, filter kit and fixings to hand. Read through the instructions fully before starting.
Mark And Cut The Diffuser Opening: Use the tear-out template from the product packaging lid to trace the diffuser shape between joists at the chosen position. The aperture is elliptical to accommodate the hall-control PCB; orient it so the controls will be easy to access from the landing (not over a stair void). Cut the opening cleanly, offer the diffuser up and fix it with the supplied screws and plugs.
Connect The Diffuser Loom: With the diffuser fixed, plug the supplied loom from the diffuser into the mating connector on the fan unit (located in the rear recess). Clip the diffuser cap to the frame using the built-in press-on clips.
Fit The NOx And Particulate Filters: Place the circular carbon filter over the central intake hole and clamp it using the metal retaining plate and the four domed screws provided. Fit the ePM10 particulate filter by clipping its metal hoop into the moulded clips. Repeat the process for the second inlet so both sides carry carbon and particulate filters.
Mount The Fan Unit: The standard method is suspension from a convenient roof timber using the supplied cord (unit mass approximately 3.5kg). Ensure a secure fixing point. If you prefer a rigid mount, install the optional anti-vibration kit to the joists as directed, maintaining the spacer height and avoiding over-tightening. Keep enough clearance for future filter changes.
Connect And Secure The Duct: Push the flexible duct fully over the fan outlet spigot and secure with the supplied tie, then repeat at the diffuser spigot. Keep the route under 2m, avoid tight bends, and make every joint airtight. Do not install the duct in a compressed state.
Complete The Electrical Connection: Fix the pre-wired power-supply module to a suitable timber surface and have a qualified electrician connect it via a fused spur to a 230V, 50Hz supply with a 1A fuse and a suitable means of isolation. Dress the low-voltage output neatly to the fan. Where smoke or CO alarms with relay bases are installed, connect the shutdown link so the fan stops automatically on alarm (mandatory in three-storey properties).
Commission The Unit From The Hall Control: Restore power. From the diffuser control, set the airflow step to suit the dwelling and select the desired temperature response profile so the loft-temperature sensor can manage behaviour (for example, increased airflow when loft air is warmer than the home, and standby in very hot lofts). Verify a smooth, even supply at the diffuser and quiet running in the loft, then label the isolator and record the chosen settings.
Explain to the household that the system supplies a gentle, filtered airflow at the head of the landing continuously. The hall control allows simple adjustment of airflow and temperature response if needed.
In normal use the unit is hands-off: leave the isolator on, keep internal doors undercut or slightly ajar to let air move through the home, and use local extract fans in kitchens and bathrooms as usual because PIV complements local extract.
The NOx configuration uses two stages at each inlet: A Carbon Filter that targets traffic-related gases and an ePM10 particulate filter for coarse dust and fibres. For the NOx function to remain effective, replace the Carbon Filters (DRI-NOX-KIT-REPLACE) every 2 years as recommended by the manufacturer.
Inspect the particulate filters periodically and renew them if visibly loaded or damaged; they are designed for easy clip-in replacement once the retainers are released. After maintenance, ensure all covers are secured before re-energising.
If airflow feels weak, first check that the duct is not compressed or kinked and that all joints are airtight. Confirm the diffuser was positioned with the specified clearances and away from smoke alarms, and that the selected speed setting is appropriate for the property.
If the unit does not run, check the local isolator, the fused spur and the power-supply module fixings. If the fan stops during a smoke or CO alarm, this is expected behaviour where the shutdown link is installed; it will resume once the alarm clears.
If unusual noise or vibration occurs, recheck the suspension or anti-vibration fixings and that the filters are seated correctly beneath their retainers.
For electrical or control issues, ask a qualified electrician to verify the supply and connections.
For the most effective whole-home moisture and pollution control, keep trickle vents open, avoid blocking the diffuser with fittings, and maintain a clear path for air down the stairwell. If the household size or moisture load increases, it is acceptable to raise the airflow by one step and review comfort over the next week or two.
Record any changes to speed and profile so future maintenance is straightforward, and replace the carbon filters at the recommended interval to preserve NOx reduction performance.
A) The Nuaire Drimaster ECO-NOX-HC is a loft-mounted Positive Input Ventilation unit with hall-mounted controls that is purpose-built for homes exposed to roadside pollution. It gently supplies filtered, tempered air from the loft into the central hallway via a discreet ceiling diffuser, creating a slight, continuous positive pressure that dilutes indoor moisture, odours and everyday pollutants. Stale, humid air is then pushed out through natural leakage paths and existing extract fans, which helps to prevent window condensation and the damp conditions that allow black mould to thrive. What distinguishes the ECO-NOX-HC from standard PIV models is the dual-stage filtration fitted at each air inlet: an ePM10 particulate element to capture everyday dust and pollen, plus a dedicated carbon cartridge pack to adsorb traffic-related gases such as nitrogen dioxide (NO₂). Commissioning and adjustments are made at the diffuser, so there is no routine need to enter the loft. The result is whole-home background ventilation with targeted NOx reduction for improved comfort and indoor air quality.
A) The Nuaire Drimaster ECO-NOX-HC uses a twin-media approach at each inlet to target both particles and traffic-related gases. The ePM10 filter removes coarse particulates typically found in loft and outdoor air, while the paired carbon cartridge contains adsorptive media that binds gaseous pollutants including NO₂, the key component of roadside NOx. This dual stage was independently BRE-tested and demonstrated up to 80% reduction of NOx ingress at the point of entry, which is particularly valuable in properties close to busy roads or junctions. Because adsorption capacity diminishes with use, the carbon cartridges are treated as a scheduled consumable and should be replaced every two years to maintain performance. The system’s continuous, gentle airflow then distributes the cleaner supply air through the dwelling, steadily displacing stale air and pollutants. Together, these measures provide a measurable uplift in indoor air quality while tackling damp and condensation.
A) The Nuaire Drimaster ECO-NOX-HC is ideal for homes in traffic-influenced areas, Air Quality Management Areas and streets with frequent bus or heavy-goods movements where NO₂ levels are a concern. It is equally appropriate where occupants report stuffiness, odours and recurring window condensation, because the Positive Input Ventilation principle steadily lowers indoor humidity and pollutant build-up. Typical applications include terraced and semi-detached houses with lofts, top-floor flats within houses that have usable loft spaces, and retrofit programmes where external wall penetrations are undesirable. The model’s dual filtration makes particular sense for households with respiratory sensitivities, small children or those seeking a practical IAQ improvement without moving away from busy roads. Where the property has three storeys, the NOX-HC may still be specified but must be installed with the appropriate safety interlocks to smoke/CO alarms; for three-storey dwellings requiring an intumescent stairwell diffuser, a dedicated Drimaster three-storey variant should be considered. In short, choose ECO-NOX-HC whenever roadside air quality and domestic moisture issues need addressing together.
A) Both models deliver the same proven PIV benefit of steady, filtered supply air that dilutes indoor humidity and pollutants, with commissioning and adjustment from the hall diffuser. The Nuaire Drimaster ECO-NOX-HC, however, introduces dedicated carbon cartridges alongside ePM10 filters at each inlet specifically to adsorb NOx, with BRE testing demonstrating up to 80% reduction at the point of entry. Because the carbon media adds airflow resistance, ECO-NOX-HC is configured to operate on the higher speed steps of the Drimaster range (typically steps 3–6) to achieve design flow, whereas a standard ECO-HC may run at lower steps for the same dwelling. Maintenance intervals also differ: the NOx model requires carbon cartridge replacement every two years, while the ePM10 filters are checked every two years and replaced at least every five. Despite the enhanced filtration, the motor remains energy efficient with very low running power, and all everyday controls remain on the ceiling diffuser for convenience. In short, ECO-NOX-HC is the go-to choice when roadside pollution is a priority alongside moisture control.
A) Commissioning is carried out at the hall-control diffuser, which presents a simple display and push-button interface for speed selection and temperature response. First, choose an airflow step appropriate to the size and occupancy of the dwelling; because the carbon media increases resistance, expect to use steps 3–6, delivering typical supply ranges of roughly 18–41 l/s. Next, select a temperature profile: a normal mode holds the chosen background rate; a heat-recovery mode raises airflow when loft air is warmer than the home to capture gentle warmth; and a hot-weather standby protects comfort by pausing the fan in very hot lofts. The diffuser’s indicators confirm settings, and a five-year service reminder appears as “C” when filter checks are due. After commissioning, stand below the diffuser to confirm a smooth, even discharge across the ceiling, then note the chosen settings for the handover. Because all controls are at the diffuser, seasonal fine-tuning is straightforward without loft access.
A) Place the diffuser centrally on the landing or hallway ceiling so the supply air can spread across the underside of the ceiling and then cascade through the dwelling. Respect the manufacturer’s minimum wall clearances, which scale with speed (for example 100mm at low settings rising to up to 1000mm at the highest), to avoid boundary effects and ensure even throw. Keep at least 1 metre away from any smoke alarm; if this cannot be achieved, fit the supplied air dams to close two sides of the diffuser so discharge is directed across at least 1.5 metres of unobstructed ceiling away from the alarm head. Avoid siting directly over a stair void, and orient the hall-control face so the display is easy to view and operate. In the loft, keep the flexible duct short, smooth and uncompressed, with airtight joints, and do not pack insulation tightly around the diffuser body. Correct placement is key to quiet, draught-free performance and avoids nuisance interaction with alarms.
A) The Nuaire Drimaster ECO-NOX-HC should be suspended from a sound roof timber using the supplied cord, or mounted on joists with the optional anti-vibration kit (code 771393) if a rigid fixing is preferred. Maintain clearance around the external filter housings so service access is unhindered and the intakes are not obstructed by insulation. Plan a short, direct duct run to the diffuser and keep the flexible duct under the recommended maximum of 2 metres, avoiding tight bends and any compression that would increase resistance or noise. The pre-wired power-supply module should be fixed to a suitable timber and connected via a fused spur and local isolator by a qualified electrician, with low-voltage leads neatly dressed to the fan. Ensure the loft itself has general ventilation, water tanks are lidded, pipes lagged and the hatch well sealed. A careful install preserves the unit’s low noise and low energy use while delivering design airflow through the additional filtration.
A) Yes. The Nuaire Drimaster ECO-NOX-HC is designed to help you meet Approved Document F (ventilation) by providing steady whole-dwelling background dilution, while its ultra-low running power supports Approved Document L (energy efficiency). The model sits within the BBA Agrément certification that covers the Drimaster-ECO loft-mounted PIV range, providing specifiers and landlords with assurance on design intent and fitness for purpose. Its distinctive attribute is the integrated NOx filtration, which has been independently BRE-tested to show up to 80% reduction of NOx at the point of entry when the twin carbon cartridges and ePM10 elements are fitted as supplied. The hall-control interface simplifies compliance checks because speeds, modes and service prompts are visible at the diffuser without loft access. When installed and commissioned to guidance, ECO-NOX-HC forms part of a compliant, low-energy approach to condensation, mould and indoor air quality management in dwellings with lofts.
A) Despite its enhanced filtration, the Nuaire Drimaster ECO-NOX-HC uses a highly efficient EC motor with typical electrical demand in the region of 1.6–15.3 watts across its speed range. In practical terms, at common UK electricity prices that translates to roughly 1–10 pence per day for continuous background operation, depending on the commissioned speed and your tariff. There is no separate in-line heater on this model, so the fan’s very low demand dominates running costs year-round. Intelligent temperature response helps further by boosting only when loft air provides a comfort advantage and pausing in very hot lofts to avoid introducing unwanted heat. Compared with the cost of addressing mould damage and high indoor humidity by other means, continuous PIV represents an economical, set-and-forget strategy. As always, your exact cost will scale with your chosen speed, dwelling leakage and energy tariff, but ECO-NOX-HC is engineered to be inexpensive to run.
A) The Nuaire Drimaster ECO-NOX-HC is designed for unobtrusive comfort, with a diffuser that spreads air across the ceiling plane at low velocity so the supply “washes” the hallway gently rather than blowing directly onto occupants. Keeping the duct short, round and uncompressed and making all joints airtight reduces system resistance and self-generated noise; suspension or anti-vibration mounting prevents structure-borne transmission into the ceiling. Because the unit runs continuously at a modest background speed, it avoids the start/stop roar and door-slam effects associated with intermittent extract-only strategies. During warmer loft periods the fan may boost slightly under its heat-recovery logic, but the throw pattern remains controlled and comfort-focused. Proper placement away from obstructions, and sensible separation from smoke alarms, also prevents turbulence and whistle. With these good practices, most households perceive only fresher air rather than audible fan noise.
A) Maintenance is simple and signposted at the diffuser. The hall-control display presents a service reminder after the recommended interval, shown as a “C”, prompting a check of the filtration. On NOx models, the carbon cartridges should be replaced every two years to maintain adsorption capacity for nitrogen dioxide and other traffic-related gases. The ePM10 particulate filters should be inspected every two years and replaced at least every five years, or earlier if visibly loaded, to keep intake resistance low and airflow on target. All consumables are supplied as matched kits for NOX models to ensure the correct combination of carbon media and particulate elements is fitted each time. After replacement, ensure all retainers are fully engaged, restore power and confirm a gentle, even discharge at the diffuser; then clear any service prompt at the controls in line with the instructions.
A) Begin by isolating the unit at the local spur or consumer unit and ensuring safe, boarded access in the loft with good lighting; never step on unboarded plasterboard ceilings. Each inlet carries two elements: a circular carbon cartridge clamped over the intake and an ePM10 filter hoop that clips into moulded retainers. Release the metal clamp plate and domed screws to remove the carbon element, then unclip the ePM10 filter; bag used filters promptly to minimise dust. Lightly dust the seating faces and gaskets with a soft brush or low-power vacuum—do not use water or solvents—and check retainers are intact. Fit the new ePM10 filter squarely, then place the carbon cartridge centrally over the intake and refit the clamp plate evenly so it seals without bowing. Repeat on the second side, restore power, confirm airflow at the diffuser and clear any “C” reminder from the hall-control display.
A) A qualified electrician must complete the fixed wiring, connecting the pre-wired power-supply module via a fused spur to a 230V, 50Hz supply with an appropriate means of all-pole isolation. The module then feeds the fan at low voltage; dress this output neatly, keeping at least 50mm from other cables as good EMC practice. If the property has three storeys, you must interlock the PIV with compatible smoke or carbon-monoxide alarms using relay bases so the unit shuts down automatically on an alarm condition, resuming once the alarm clears. Maintain safe loft practices at all times: ensure general loft ventilation, keep clear of hot flues, and do not obstruct any fire barriers. At the diffuser, maintain the recommended separation from smoke alarms and, if necessary, use the supplied air dams to direct airflow away from a nearby alarm head. Record commissioning settings and any interlocks in the handover notes for future maintenance.
A) The most common issues arise from airflow restriction and siting. Do not compress the flexible duct under insulation or force it around tight bends; keep the run under the recommended 2 metres with airtight joints to preserve performance and low noise. Avoid placing the diffuser too close to walls, pendant lights or smoke alarms; respect the minimum clearances and use air dams if needed to direct flow across open ceiling. Never operate the unit without its filters or with non-genuine media, as this undermines both NOx performance and fan protection. For three-storey dwellings, do not omit the mandatory alarm shut-down interlock. Finally, remember that carbon adsorption capacity is finite; if cartridges are not replaced on schedule, NOx reduction will decline. Following the supplied guidance preserves the unit’s advantages and minimises call-backs.
A) The Nuaire Drimaster ECO-NOX-HC complements local extracts rather than replacing them. The PIV provides a constant, gentle supply of filtered air that keeps humidity and pollutants low throughout the dwelling, while room-specific extract fans remove short-term peaks directly at source in bathrooms and kitchens. This paired strategy is best practice: leave the ECO-NOX-HC running continuously, encourage occupants to use local extracts during steamy or odorous activities, and keep trickle vents open so there are easy air paths. Over time, the PIV’s steady background ventilation reduces the baseline moisture load, so local extracts work more effectively and for less time. The result is fewer condensation events, less mustiness and a consistently fresher indoor environment, with the added benefit of NOx reduction at the point of entry. Together, these systems deliver better overall air quality with minimal energy use.
A) Because the NOx filtration adds resistance, the Nuaire Drimaster ECO-NOX-HC is intended to operate on the higher speed steps of the Drimaster range—typically steps 3 to 6—with indicative supply rates from roughly 18 to 41 l/s depending on the chosen setting and property characteristics. That range comfortably covers most UK houses with lofts, providing adequate dilution for everyday moisture and pollutant loads while keeping noise and energy use modest. The loft-temperature sensor helps the system balance comfort and efficiency across the seasons by boosting when loft air is usefully warm and standing by in very hot lofts. As with any ventilation system, actual performance depends on siting, duct quality, dwelling leakage and the continued health of the filters. Commissioning should therefore confirm a gentle, even discharge at the diffuser and a noticeable, background sense of freshness as the system settles in over the first few days.
A) The Nuaire Drimaster ECO-NOX-HC carries a seven-year warranty structured as one year Parts & Labour followed by a further six years Parts (UK & Ireland). This reflects confidence in the EC motor, electronics, hall-control interface and the robust casing designed for continuous background operation. Consumable items—namely the carbon cartridges and ePM10 filters—are excluded from extended coverage beyond supply quality because they are designed to be replaced at the stated intervals to maintain performance. The warranty assumes installation and commissioning have followed the manufacturer’s guidance, including correct electrical isolation, appropriate siting, airtight ductwork and the use of genuine replacement parts. Keeping a record of the installation date, speed and temperature settings, and dates of filter changes helps streamline any future support queries. As with all warranties, accidental damage or misuse falls outside the scope.
A) If airflow at the diffuser feels weak, first check the obvious: ensure the flexible duct is not kinked or compressed, that all joints are airtight and that the diffuser’s clearances are respected. Confirm the unit is set on an appropriate speed step for a NOx model—typically 3–6—because lower steps may not overcome the filtration resistance. Where musty odours return, inspect the ePM10 filters and verify the carbon cartridges are within their two-year service life; renew if loaded or out of date. If the unit does not run, verify the local isolator and fused spur, then confirm the power-supply module fixings in the loft; only a qualified electrician should open electrical enclosures. Should the fan pause during very hot weather, that is likely hot-weather standby and will clear automatically as loft temperatures fall. After any maintenance, recheck for a smooth, even discharge at the diffuser and ensure the hall-control display shows normal operation.
A) The Nuaire Drimaster ECO-NOX-HC can be installed in three-storey dwellings that have a usable loft, but additional life-safety measures apply. Specifically, you must provide an automatic shut-down link to compatible smoke or carbon-monoxide alarms via relay bases so the unit stops on an alarm condition and restarts once the alarm clears. Maintain increased care in diffuser siting on the top-floor landing to avoid directing airflow at nearby alarm heads; keep at least 1 metre separation and, where needed, use the supplied air dams to direct the throw across open ceiling. In some three-storey cases where a stairwell penetration must have an intumescent closure, a Drimaster three-storey model with a dedicated aluminium fire-block diffuser may be more appropriate. Discuss the building configuration with your installer so the chosen model and safety provisions align with regulation and best practice. With the correct interlocks and siting, PIV remains an effective whole-home strategy in taller homes.
A) A few simple practices maximise the benefit. Leave the local isolator on so the unit can run continuously, because steady background dilution is the essence of PIV performance. Keep internal doors undercut or slightly ajar so the fresh supply can move down the hallway and through rooms, and continue to use kitchen and bathroom extracts during steamy activities. Do not obstruct the diffuser with lampshades or decorations, and keep the face clean with a light vacuum during routine housekeeping. Replace carbon cartridges every two years and the ePM10 filters at least every five (or sooner if visibly loaded) so airflow remains within the intended range and NOx adsorption stays effective. If household size or moisture load changes—more occupants, frequent laundry drying indoors—raise the airflow by one step and review comfort over the following week, noting any changes for future maintenance.
A) Most homes notice a fresher feel within days as the Nuaire Drimaster ECO-NOX-HC establishes steady background airflow and begins diluting humidity and pollutants continuously. Window condensation typically reduces first in circulation spaces, with bedrooms often following as occupants adopt supportive habits such as keeping doors slightly ajar and using local extracts. Black mould already present will not disappear on its own, but by keeping surfaces drier the system helps prevent regrowth after cleaning and treatment. The NOx benefit is immediate at the point of entry because the carbon cartridges adsorb nitrogen dioxide and related gases from day one, provided the cartridges are fresh and correctly fitted. As seasons change, the loft-temperature logic helps maintain comfort by boosting with useful warmth and pausing in very hot lofts. In short, improvements start quickly and consolidate over the first few weeks as the home stabilises to a drier, cleaner baseline.
Description
Installation
FAQ's
Data Sheets