Soudal Fire Silicone B1 FR - Fire Rated Neutral Silicone
Soudal Fire Silicone B1 FR is a Neutral Cure, FIRE RATED Silicone Sealant which can be applied on to all common construction materials including glass, plastics, masonry substrates, metals and wood.
Supplied in 310ml Cartridges, in White colour only.
Free Delivery
on orders over £100(ex. VAT, mainland UK only)
Free Help & Advice
Call 01355 222 777
Mon.-Fri 8:30am - 4:15pm, or email us
Next Day Delivery
Order Before 2:00pm for Same Day Despatch (terms apply)
Great Service
A proudly independent family business with 40 years experience
Soudal Fire Silicone B1 FR
Soudal Fire Silicone B1 FR is Solvent Free and Virtually Odourless with Primerless adhesion on all common construction materials (i.e glass, plastics, masonry substrates, metals and wood). High movement capability. Resistant to UV, rain, ozone and many chemicals.
Soudal Fire Silicone B1 FR Conforms to all international standards including CE Marking.
Soudal Fire Silicone B1 FR Conforms to the DIN4102 B1 standard for fire retardancy and has a fire rating of up to 4 hours in certain joint configurations (EN 1366 Part 4 NN713.020 – BS 476/20).
Product Benefits:
-
Very easy to apply
-
Colourfast and UV Resistant
-
Remains permanently elastic after full cure
-
Very good adhesion on most surfaces
-
Weatherproof
-
EN13501-1 - Reaction to Fire, Class E
-
ETAG-026 - Part 1, Part 3
-
EN1366-4 - Fire Resistance, up to 4 Hours depending on joint configuration.
Typical Applications:
-
For use in External and Internal Passive Fire Systems as an Elastic Joint Sealant.
-
Installation of Fire Retardant Window and Door Frames.
-
For use in Fire Retardant Expansion and Connection Joints, and Penetration Seals.
Surface Preparation:
Surfaces should be clean, dry, free of dust and grease.
Porous substrates should be primed with Soudal Primer 150. Soudal Surface Activator will improve adhesion on smooth surfaces.
We recommend a preliminary compatibility test.
Application Method:
-
Application Method: With a Caulking Gun. Finish with spatula or filling knife.
-
Cleaning: Clean uncured product with a white spirit immediately after use.
-
Finishing: Spray with a Soapy Solution before skinning. Finish with Soudaglatt Smoothing Tool.
-
Repair: With the same material
Joint Dimensions:
-
Minimum Width for Joints: 5mm
-
Maximum Width for Joints: 30mm
-
Recommendation Sealing Jobs: Joint Width = 2 x Joint Depth.
Approvals:
-
Test Report 9297: University of Ghent
-
NBN 713.020: EN 1366-4
-
BS 476:Part 20: Warrington Fire Research Report
-
DIN4102-B1: Institut für Bautechnik, Berlin
-
TNO-rapport 2000-CVB-R00703
Test Results:
| Test Report 9297 | ||||
|---|---|---|---|---|
| Wall Thickness | Width of Joint | Depth of Joint | Application | Fire Rating |
| 100mm | 11mm | 10mm | Doublesided | 146min TI Rating EI 120 202 min FR Rating E 180 |
| 100mm | 33mm | 20mm | Doublesided | 116min TI Rating EI 90 187 min FR Rating E 180 |
| 200mm | 11mm | 10mm | Doublesided | >240 min TI >240 min FR Rating EI 240 |
| 200mm | 31mm | 20mm | Doublesided | 225 min TI Rating EI 180 >240 min FR Rating E 240 |
TI = Thermal Insulation; the time during which the temperature on the unexposed side of the wall does not rise by more than 180°C
FR = Flame Resistance; the time during which the joints stops flames from penetrating the wall
Fire Rating: Draft European Commission Decision RG N170 REV.1
Soudal Fire Silicone B1 FR
Soudal Fire Silicone B1 FR is Solvent Free and Virtually Odourless with Primerless adhesion on all common construction materials (i.e glass, plastics, masonry substrates, metals and wood). High movement capability. Resistant to UV, rain, ozone and many chemicals.
Soudal Fire Silicone B1 FR Conforms to all international standards including CE Marking.
Soudal Fire Silicone B1 FR Conforms to the DIN4102 B1 standard for fire retardancy and has a fire rating of up to 4 hours in certain joint configurations (EN 1366 Part 4 NN713.020 – BS 476/20).
Product Benefits:
-
Very easy to apply
-
Colourfast and UV Resistant
-
Remains permanently elastic after full cure
-
Very good adhesion on most surfaces
-
Weatherproof
-
EN13501-1 - Reaction to Fire, Class E
-
ETAG-026 - Part 1, Part 3
-
EN1366-4 - Fire Resistance, up to 4 Hours depending on joint configuration.
Typical Applications:
-
For use in External and Internal Passive Fire Systems as an Elastic Joint Sealant.
-
Installation of Fire Retardant Window and Door Frames.
-
For use in Fire Retardant Expansion and Connection Joints, and Penetration Seals.
Surface Preparation:
Surfaces should be clean, dry, free of dust and grease.
Porous substrates should be primed with Soudal Primer 150. Soudal Surface Activator will improve adhesion on smooth surfaces.
We recommend a preliminary compatibility test.
Application Method:
-
Application Method: With a Caulking Gun. Finish with spatula or filling knife.
-
Cleaning: Clean uncured product with a white spirit immediately after use.
-
Finishing: Spray with a Soapy Solution before skinning. Finish with Soudaglatt Smoothing Tool.
-
Repair: With the same material
Joint Dimensions:
-
Minimum Width for Joints: 5mm
-
Maximum Width for Joints: 30mm
-
Recommendation Sealing Jobs: Joint Width = 2 x Joint Depth.
Approvals:
-
Test Report 9297: University of Ghent
-
NBN 713.020: EN 1366-4
-
BS 476:Part 20: Warrington Fire Research Report
-
DIN4102-B1: Institut für Bautechnik, Berlin
-
TNO-rapport 2000-CVB-R00703
Test Results:
| Test Report 9297 | ||||
|---|---|---|---|---|
| Wall Thickness | Width of Joint | Depth of Joint | Application | Fire Rating |
| 100mm | 11mm | 10mm | Doublesided | 146min TI Rating EI 120 202 min FR Rating E 180 |
| 100mm | 33mm | 20mm | Doublesided | 116min TI Rating EI 90 187 min FR Rating E 180 |
| 200mm | 11mm | 10mm | Doublesided | >240 min TI >240 min FR Rating EI 240 |
| 200mm | 31mm | 20mm | Doublesided | 225 min TI Rating EI 180 >240 min FR Rating E 240 |
TI = Thermal Insulation; the time during which the temperature on the unexposed side of the wall does not rise by more than 180°C
FR = Flame Resistance; the time during which the joints stops flames from penetrating the wall
Fire Rating: Draft European Commission Decision RG N170 REV.1