The Nuaire Flatmaster Replacement Filter (Model FLAT-FILTERKIT) is the genuine service filter for the Flatmaster and Flatmaster 2000 Positive Input Ventilation units.
Designed to keep airflow, efficiency and air quality at their best, it captures coarse house dust and fibres before they reach the fan, helping the system to reduce condensation and black mould effectively.
The filter is quick to replace as part of routine maintenance and is typically renewed every 12 months, with the interval shortened where local conditions are dusty or polluted.
Unit
Easy to order, competitive price, arrived promptly. Great service, thank you.
Thanks for the great review, glad the Nuaire Flatmaster replacement filter was exactly as described and arrived promptly. Appreciate the shout on price and service. If you need another filter or anything else, we’re here to help.
Apologies my review is 5 stars! Unsure why its only showing 4 😃 Thanks again !
Thanks for the follow-up and amending the original review! No worries about the stars, we really appreciate the five-star vote of confidence. Great to hear the Flatmaster filter did the trick. If you need anything else for the PIV, we’re here to help!
I needed a new filter for our PIV unit and found this company online. Great speedy delivery and PIV doing its intended job again with new filter.
Thanks for choosing us and for the review — delighted the Flatmaster filter arrived quickly and got your PIV doing its job again. If there’s anything we could have done to earn that fifth star, please let us know so we can improve for next time.
Free Delivery
on orders over £100(ex. VAT, mainland UK only)
Free Help & Advice
Call 01355 222 777Mon.-Fri 8:30am - 4:15pm, or email us
Next Day Delivery
Order Before 2:30pm for Same Day Despatch (terms apply)
Great Service
A proudly independent family business with 40 years experience
✔️ Genuine replacement filter engineered specifically for Nuaire Flatmaster and Flatmaster 2000 Positive Input Ventilation units.
✔️ Captures coarse house dust, fibres and debris to protect the fan and maintain commissioned airflow.
✔️ Matched filter media keeps pressure loss low, supporting quiet, energy-efficient operation and stable day-to-day performance.
✔️ Quick, tool-free replacement during routine maintenance, locating neatly in the existing Flatmaster filter housing.
✔️ Typical service interval is twelve months, shortened where conditions are dusty, polluted or higher occupancy.
A Positive Input Ventilation (PIV) system relies on a clean, free-flowing intake to deliver a gentle, continuous supply of fresh air into the dwelling. Engineered specifically for the Flatmaster chassis, the Nuaire Flatmaster Replacement Filter provides that first line of defence by intercepting coarse particulates such as house dust, fibres, pet dander and airborne debris. By protecting the fan assembly, it stabilises airflow at the commissioned rate and supports quiet day-to-day operation. Because the media is precisely matched to the unit’s fan characteristics, pressure loss remains low when clean, preserving energy efficiency and reducing the likelihood of noise from restricted airflow pathways.
Using the correct, genuine filter also simplifies upkeep. The element locates neatly in the Flatmaster / Flatmaster 2000 filter housing and can be replaced in minutes during a routine visit without disturbing the rest of the installation. Nuaire advises renewing the filter annually as part of the maintenance schedule, or sooner under adverse environmental conditions, to keep performance on target and ensure residents continue to benefit from reduced condensation and improved indoor air quality.
Genuine Fit And Performance: Purpose-designed for Nuaire Flatmaster and Flatmaster 2000 units, the filter seats correctly in the factory housing, preserves the intended airflow characteristics and avoids the added resistance and noise often associated with generic alternatives.
Maintains Airflow, Efficiency And Low Noise: Clean media keeps pressure drop low so the fan can deliver its commissioned rate without overworking, helping the system stay quiet and energy-efficient while it combats condensation and stale odours.
Supports Healthy Indoor Air: Captures coarse dust, fibres and everyday debris at the intake, improving the quality of supply air before it diffuses through the home and helping protect finishes from dust deposition.
Quick, Predictable Maintenance: Annual replacement is simple and fast, minimising downtime and making it easy to align with routine property visits; Nuaire notes the interval may be shortened where conditions demand.
Routine Servicing Of Flatmaster Systems: Homeowners, landlords and maintenance teams replacing filters on installed Flatmaster units to sustain condensation control and everyday indoor air quality.
Flatmaster 2000L/2000R Maintenance: Direct replacement for Flatmaster 2000 models, ensuring the correct fit and maintaining the manufacturer’s recommended service regime.
Urban And High-Dust Locations: Properties near busy roads, construction activity or high-pollen areas where filters benefit from more frequent renewal to protect airflow and comfort.
Social Housing And PRS Portfolios: Estate-wide programmes where a single, genuine filter simplifies reordering and supports consistent aftercare across multiple addresses.
Work only with safe access, good lighting and a stable step-stool if the unit is mounted high on a wall. Isolate the Flatmaster at its local isolator or consumer unit before removing the front cover; this avoids contact with moving parts and live components while you work.
Wear gloves, eye protection and a dust mask, as used filters can shed fine dust. Keep the area around the unit clear so you can remove and refit the cover without obstruction, and do not place tools where they could fall into the unit or the duct openings. When finished, ensure the cover is securely refitted before restoring power.
Plan safe access to the Flatmaster’s front cover and make sure you can reach the fixings at the top and bottom edge of the cover.
Have a soft brush or vacuum with a gentle brush attachment available to remove loose dust from the filter seat, and a bag or sheet to contain the old filter for tidy disposal. The unit should be accessible from the front so the cover can be removed and refitted without straining cables or ductwork.
Replace the filter at least every 12 months, and sooner in dusty locations or near busy roads. Using the correct filter maintains airflow, energy efficiency and noise performance; fitting improvised media or operating with a clogged filter can impair effectiveness and may invalidate the product warranty.
Do not run the unit with the cover removed, do not vacuum the fan or electronics, and avoid bending or creasing the new filter during installation. After replacement, always restore power and check the unit is running smoothly at the commissioned speed.
Isolate The Power: Turn off the Flatmaster at its local isolator or the consumer unit and allow the fan to come to rest. Stand securely so you can work comfortably at the unit.
Remove The Front Cover: Locate the cover fixings at the top and bottom edges, loosen them and lift the cover clear. Place the cover somewhere clean so dust will not transfer to the sealing faces when refitting.
Withdraw The Used Filter: The filter sits immediately behind the front cover. Slide it out carefully to avoid shedding dust. Place it straight into a bag for disposal to keep the work area clean.
Clean The Filter Seating Area: With a soft brush or a vacuum on a gentle setting, remove loose dust from the filter ledges and surrounding casing. Do not disturb wiring, and do not allow debris to fall into the fan scroll or duct spigots.
Fit The New Filter: Offer the replacement element squarely into the guides, ensuring it sits flat and fully home on all sides. Take care not to crease the media and confirm there are no gaps around the perimeter.
Refit The Front Cover: Align the cover, engage it on the casing and tighten the top and bottom fixings evenly so the cover sits flush. Do not overtighten.
Restore Power And Check Operation: Re-energise the unit. From the discharge grille, confirm a gentle, steady airflow and listen for smooth running at the normal commissioned speed. If your maintenance routine includes any diffuser-side checks, carry them out now.
If the front cover will not seat properly after fitting the new filter, check the element is fully home in its guides and that no part of the media is trapped against the cover edge.
If airflow seems weak after replacement, recheck that the cover fixings are tight, that the new filter is not mis-seated or folded, and that supply and discharge ducts are secure at their spigots.
If the unit does not run after the filter change, verify the local isolator and protective device, then confirm the cover is correctly refitted and that no internal component has been disturbed.
For persistent issues, consult a qualified electrician or Nuaire after-sales support, quoting your unit’s serial number and the filter part code.
A) The Nuaire Flatmaster Replacement Filter (FLAT-FILTERKIT) is the genuine intake filter for Nuaire’s Flatmaster and Flatmaster 2000 Positive Input Ventilation (PIV) units. It traps coarse dust, fibres, pet dander and everyday airborne debris before air reaches the fan, helping the system maintain its commissioned airflow, low noise and energy efficiency. By keeping the intake clear, the filter supports the Flatmaster’s role in reducing condensation and black mould, improving everyday indoor air quality throughout the dwelling. Using the correct, matched media matters because the pressure loss of the genuine filter is designed to suit the Flatmaster fan curve; improvised or clogged media can restrict flow, raise noise and undermine performance. In short, a clean, correctly seated FLAT-FILTERKIT preserves the whole system’s effectiveness and protects the fan assembly over the long term.
A) The FLAT-FILTERKIT is designed for Nuaire Flatmaster and Flatmaster 2000 models and is widely listed as suitable for post-2001 units (including 2000L and 2000R variants). This genuine fit ensures the element locates properly in the factory housing without trimming or adapting and maintains the intended airflow characteristics of the appliance. If your unit was manufactured before 2001 or you are unsure of the model suffix, check the data label on the unit or your installation paperwork to confirm build year and model, then match to the filter kit specification. Reputable product listings and trade guidance consistently reference Flatmaster and Flatmaster 2000 compatibility for units produced after 2001, reinforcing the intended application of this filter kit.
A) As good practice, plan to change the Nuaire Flatmaster Replacement Filter every 12 months to keep airflow, efficiency and noise performance on target. In cleaner, low-dust homes some suppliers note a service life of up to 1–2 years; conversely, homes near busy roads, high-pollen areas or construction dust often benefit from shorter intervals. Practical signs that the filter is due include a noticeable reduction in airflow at the grille, a return of musty odours or surface condensation, or visible loading of the filter media. Routine, time-based replacement is preferable to waiting for symptoms, as PIV relies on a free-flowing intake to deliver its gentle, continuous supply. Aligning filter changes with annual property checks or boiler services makes scheduling straightforward and helps maintain consistent condensation control.
A) The replacement element used in Flatmaster systems is commonly described as a coarse, G-class intake filter (often referenced as G3). This grade is well matched to continuous background ventilation because it captures everyday household dust and fibres with low resistance when clean. That balance preserves the commissioned flow rate and helps the fan remain quiet and economical. Importantly, the Flatmaster filter is not a fine HEPA element; finer grades increase pressure drop and can compromise the low-energy, always-on duty expected of PIV. If you require additional gas-phase or fine particulate filtration, consider solutions designed specifically for that purpose rather than substituting media. For the Flatmaster’s intended role, whole-dwelling dilution ventilation, its genuine G-class element provides the right compromise between capture efficiency and system performance.
A) First isolate power at the local isolator or consumer unit and let the fan stop. Remove the front cover by releasing the top and bottom fixings, then slide the used filter straight out and bag it immediately to contain dust. Lightly vacuum or brush the seating faces, avoid disturbing wiring or letting debris fall into the fan scroll or duct spigots. Offer the new FLAT-FILTERKIT squarely into the guides so it sits fully home without creases or gaps, then refit the cover and tighten fixings evenly. Restore power and confirm a gentle, steady airflow at the discharge grille with smooth, quiet running. This is a quick, routine task that normally takes just a few minutes and does not require access to internal electrics beyond the isolator. Ensuring the unit is installed for front-cover access makes periodic cleaning and filter changes straightforward.
A) Genuine FLAT-FILTERKIT elements are dimensionally correct, seat positively in the Flatmaster/Flatmaster 2000 housing and deliver the pressure loss the fan was commissioned against. That means the fan doesn’t have to work harder to overcome blockage or mismatched media, so noise and energy use remain low and the airflow you set at commissioning is preserved. Generic or improvised media can add resistance, leak around the edges, shed fibres, or deform under suction, issues that reduce supply air volume and raise the risk of draught trails or whistling at the grille. Using the authentic kit also simplifies reordering, supports warranty expectations and aligns with common landlord maintenance regimes, helping estates teams sustain predictable performance across a portfolio of properties.
A) No, treat the Nuaire Flatmaster Replacement Filter as a replace-only consumable. Washing, vacuuming or shaking can damage the media, disturb fibres into the unit, and change the pore structure in ways that increase pressure drop or reduce capture efficiency. Because PIV relies on low, steady resistance at the intake, a degraded filter undermines performance and can cause the fan to sound louder than normal. The most reliable approach is to inspect periodically (for example during annual checks) and replace on schedule, or sooner if local conditions demand. Bag and dispose of used filters responsibly and avoid re-installing any element that is creased, damp, oil-contaminated or visibly deteriorated.
A) PIV works by supplying a gentle, continuous stream of fresher outside air that dilutes moisture-laden, stale indoor air and pushes it out through natural leakage paths and extracts. A clean, correctly seated FLAT-FILTERKIT ensures that supply air reaches the home at the commissioned rate without unnecessary resistance, maintaining the subtle positive pressure that breaks the condensation–damp–mould cycle. When filters become loaded, intake resistance rises, background airflow can fall, and the system’s ability to control humidity is compromised. Keeping the filter clean therefore isn’t just about hygiene, it’s fundamental to delivering the moisture control and indoor air quality improvement Flatmaster is specified to provide.
A) Tell tale signs include a perceptible drop in airflow at the discharge grille, a return of window steaming or surface condensation after showers, a faint musty odour in circulation spaces, or visible greying and dust loading of the filter media. In traffic-exposed or high-pollen locations you may also notice more frequent dusting needs. If any of these occur well before your planned service date, it is sensible to fit a new FLAT-FILTERKIT and note the new interval, many suppliers highlight that homes near busy roads or construction sites benefit from earlier replacement compared with quieter suburban settings. Proactive renewal typically restores normal airflow, reduces noise and returns the system to its usual, effective background performance.
A) Yes, the FLAT-FILTERKIT is a single, genuine element for Flatmaster and Flatmaster 2000 units regardless of left- or right-hand spigot orientation (commonly quoted as 2000L/2000R). The filter slides into the dedicated front housing, so no trimming or special tools are required, just isolate the power, remove the cover fixings, change the element and refit. Because the task is carried out from the front, there is no need to disturb duct connections or the power supply. Ensure the cover can be removed without strain and that the unit is installed with adequate clearance for periodic servicing, as advised in installation literature for the Flatmaster range.
Description
Installation
FAQ's