{"product_id":"newton-newtonite-mesh-plugs-damp-proof-membrane-fixing","title":"Newton Newtonite Mesh Plugs","description":"\u003cp\u003e\u003cspan\u003eNewton Newtonite Mesh Plugs (Newton product reference A16) are specialist fixing plugs designed for securing \u003ca rel=\"noopener\" href=\"https:\/\/www.platinumchemicals.co.uk\/products\/newton-damp-proof-membrane-803-newtonite\" target=\"_blank\"\u003e\u003cstrong\u003eNewtonite Lath Mesh Membrane\u003c\/strong\u003e\u003c\/a\u003e to internal masonry walls within the \u003ca rel=\"noopener\" href=\"https:\/\/www.platinumchemicals.co.uk\/collections\/newton-damp-proof-membrane\" target=\"_blank\"\u003e\u003cstrong\u003eNewtonite Damp Proofing System\u003c\/strong\u003e\u003c\/a\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe current blue plug design replaces the older brown version and is approximately 10mm longer, providing improved fixing stability and enhanced performance. Installed through the meshed damp proofing membrane using a 7mm SDS drilled hole, the plug anchors the membrane securely against the substrate before plaster, render or dot and dab plasterboard finishes are applied.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFor direct plastering or rendering, 16 plugs per m² should be used. For dot and dab plasterboard, 10 plugs per m² is normally sufficient.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003eDescription\u003c\/h5\u003e\n\u003ch2\u003e\u003cstrong\u003eKey Features of Newton Newtonite Mesh Plugs\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cbr\u003e✔️ Specialist fixing plugs designed to secure \u003ca rel=\"noopener\" href=\"https:\/\/www.platinumchemicals.co.uk\/products\/newton-damp-proof-membrane-803-newtonite\" target=\"_blank\"\u003e\u003cstrong\u003eNewtonite Lath Mesh Membrane\u003c\/strong\u003e\u003c\/a\u003e to internal masonry walls before plastering.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e✔️ Current blue plug replaces older brown version and is approximately 10mm longer for improved fixing stability.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e✔️ Installed through the membrane using a 7mm SDS drilled hole for a clean, secure fixing.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e✔️ Recommended at 16 plugs per m² for direct plastering or 10 per m² for dot and dab.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e✔️ Can be sealed with Newtonite 801 Mastic around the plug head for added damp proof protection.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: rgb(88, 88, 88);\"\u003ePurpose-Made Fixing Plugs For Newtonite Lath Mesh Damp Proofing Membrane\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eNewton \u003cspan\u003eNewtonite Mesh Plugs\u003c\/span\u003e are purpose-made damp proofing membrane fixings developed specifically for use with \u003ca rel=\"noopener\" href=\"https:\/\/www.platinumchemicals.co.uk\/products\/newton-damp-proof-membrane-803-newtonite\" target=\"_blank\"\u003e\u003cstrong\u003eNewtonite Lath Mesh Membrane\u003c\/strong\u003e\u003c\/a\u003e, a BBA Approved meshed damp proof membrane used within Newton’s Newtonite Damp Proofing System. Their primary role is to mechanically secure the meshed membrane to internal walls, allowing the wall finish to be effectively separated from damp or salt-contaminated masonry behind. This makes them especially useful in above-ground damp proofing, refurbishment and renovation work, particularly in situations where existing walls are affected by residual moisture, hygroscopic salts or general dampness but still require a stable and properly prepared surface for plastering, rendering or dry lining to be applied successfully and durably over the top.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: rgb(88, 88, 88);\"\u003eUpdated Blue Plug Design With Improved Length And Fixing Stability\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eThe latest Newton \u003cspan\u003eNewtonite Mesh Plugs\u003c\/span\u003e is blue in colour and replaces the previous brown plug design, with the current blue version now representing the correct and up-to-date specification. The updated plug is approximately 10mm longer than the former version, helping to improve stability and mechanical hold when securing the membrane firmly back against the wall substrate. Installation requires a 7mm SDS drill bit to create a clean, accurate fixing hole through the membrane and into the masonry beneath. Correct plug spacing is genuinely important to ensure the membrane sits evenly and securely before finishing work begins. For direct plastering or rendering, 16 \u003cspan\u003eNewtonite Mesh Plugs\u003c\/span\u003e per square metre should be used, whilst dot and dab plasterboard applications typically require around 10 plugs per square metre.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: rgb(88, 88, 88);\"\u003eOptional Mastic Sealing For Enhanced Protection In High-Risk Damp Conditions\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eIn higher risk or more severely damp wall situations, \u003cspan\u003eNewtonite Mesh Plugs\u003c\/span\u003e can be further protected using Newtonite 801 Mastic, applied to the inside of the plug head before the plug is fixed through the membrane and driven into the wall. This helps to create a reliable damp proof seal around each individual plug head, providing additional protection at fixing penetrations where dampness levels are a particular concern. This approach is especially worthwhile where the wall conditions are more challenging and a greater degree of confidence in the fixing detail is required. For users searching for \u003cspan\u003eNewtonite Mesh Plugs\u003c\/span\u003e, Newtonite membrane fixings, damp proof membrane plugs, mesh membrane fixing plugs or internal damp proofing fixings, these plugs provide the correct and manufacturer-recommended fixing solution for Newton’s meshed damp proofing system.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cstyle\u003e\n  .pc-newton-newlath-tech-table-wrap {\n    width: 100%;\n    max-width: 100%;\n    overflow-x: auto;\n    -webkit-overflow-scrolling: touch;\n    margin: 24px 0;\n  }\n\n  .pc-newton-newlath-tech-table {\n    width: 100%;\n    min-width: 620px;\n    table-layout: fixed;\n    border-collapse: collapse;\n    font-family: inherit;\n    font-size: 16px;\n    line-height: 1.25;\n    color: #111;\n    background: #fff;\n  }\n\n  .pc-newton-newlath-tech-table col:nth-child(1) { width: 38%; }\n  .pc-newton-newlath-tech-table col:nth-child(2) { width: 62%; }\n\n  .pc-newton-newlath-tech-table th,\n  .pc-newton-newlath-tech-table td {\n    border: 5px solid #fff;\n    padding: 8px 12px;\n    vertical-align: middle;\n    font-weight: 400;\n  }\n\n  .pc-newton-newlath-tech-table .pc-main-title th {\n    background: #7f7f7f;\n    color: #fff;\n    text-align: center;\n    text-transform: uppercase;\n    font-size: 30px;\n    line-height: 1.15;\n    font-weight: 700;\n    letter-spacing: 0.2px;\n    padding: 12px 10px;\n  }\n\n  .pc-newton-newlath-tech-table .pc-column-head th {\n    background: #a6a6a6;\n    color: #111;\n    font-size: 17px;\n    line-height: 1.2;\n    font-weight: 700;\n    text-align: left;\n    padding: 10px 12px;\n  }\n\n  .pc-newton-newlath-tech-table .pc-data-row td {\n    background: #fff;\n    text-align: left;\n  }\n\n  .pc-newton-newlath-tech-table .pc-data-row.pc-grey td {\n    background: #d9d9d9;\n  }\n\n  .pc-newton-newlath-tech-table .pc-spec-cell {\n    font-weight: 700;\n  }\n\n  @media screen and (max-width: 767px) {\n    .pc-newton-newlath-tech-table {\n      font-size: 14px;\n      min-width: 600px;\n    }\n\n    .pc-newton-newlath-tech-table th,\n    .pc-newton-newlath-tech-table td {\n      padding: 7px 9px;\n      border-width: 4px;\n    }\n\n    .pc-newton-newlath-tech-table .pc-main-title th {\n      font-size: 24px;\n      padding: 10px 8px;\n    }\n\n    .pc-newton-newlath-tech-table .pc-column-head th {\n      font-size: 15px;\n      padding: 9px;\n    }\n  }\n\u003c\/style\u003e\n\u003cdiv class=\"pc-newton-newlath-tech-table-wrap\"\u003e\n\u003ctable class=\"pc-newton-newlath-tech-table\" aria-label=\"Newton Newlath Plugs Technical Information\"\u003e\n\u003ccolgroup\u003e \u003ccol\u003e \u003ccol\u003e \u003c\/colgroup\u003e\n\u003cthead\u003e\n\u003ctr class=\"pc-main-title\"\u003e\n\u003cth colspan=\"2\"\u003eTechnical Information\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-column-head\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr class=\"pc-data-row\"\u003e\n\u003ctd class=\"pc-spec-cell\"\u003eProduct Reference\u003c\/td\u003e\n\u003ctd\u003eA16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row pc-grey\"\u003e\n\u003ctd class=\"pc-spec-cell\"\u003eCurrent Plug Colour\u003c\/td\u003e\n\u003ctd\u003eBlue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row\"\u003e\n\u003ctd class=\"pc-spec-cell\"\u003ePrevious Version\u003c\/td\u003e\n\u003ctd\u003eBrown, now superseded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row pc-grey\"\u003e\n\u003ctd class=\"pc-spec-cell\"\u003ePlug Length\u003c\/td\u003e\n\u003ctd\u003eApprox. 10mm longer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row\"\u003e\n\u003ctd class=\"pc-spec-cell\"\u003eDrill Hole Size\u003c\/td\u003e\n\u003ctd\u003e7mm SDS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row pc-grey\"\u003e\n\u003ctd class=\"pc-spec-cell\"\u003eFixing Method\u003c\/td\u003e\n\u003ctd\u003eHammer driven\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row\"\u003e\n\u003ctd class=\"pc-spec-cell\"\u003eMain Use\u003c\/td\u003e\n\u003ctd\u003eMesh membrane fixing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row pc-grey\"\u003e\n\u003ctd class=\"pc-spec-cell\"\u003eSuitable Membrane\u003c\/td\u003e\n\u003ctd\u003eNewtonite Lath Mesh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row\"\u003e\n\u003ctd class=\"pc-spec-cell\"\u003eSuitable System\u003c\/td\u003e\n\u003ctd\u003eNewtonite Damp Proofing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row pc-grey\"\u003e\n\u003ctd class=\"pc-spec-cell\"\u003eSuitable Substrates\u003c\/td\u003e\n\u003ctd\u003eInternal masonry walls\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row\"\u003e\n\u003ctd class=\"pc-spec-cell\"\u003eFinish Compatibility\u003c\/td\u003e\n\u003ctd\u003ePlaster, render, plasterboard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row pc-grey\"\u003e\n\u003ctd class=\"pc-spec-cell\"\u003eDirect Finish Density\u003c\/td\u003e\n\u003ctd\u003e16 plugs\/m²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row\"\u003e\n\u003ctd class=\"pc-spec-cell\"\u003eDot And Dab Density\u003c\/td\u003e\n\u003ctd\u003e10 plugs\/m²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row pc-grey\"\u003e\n\u003ctd class=\"pc-spec-cell\"\u003eOptional Sealant\u003c\/td\u003e\n\u003ctd\u003eNewtonite 801 Mastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row\"\u003e\n\u003ctd class=\"pc-spec-cell\"\u003eMain Benefit\u003c\/td\u003e\n\u003ctd\u003eSecure damp proof separation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eProduct Benefits\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSpecialist Newtonite Membrane Fixing:\u003c\/strong\u003e \u003cspan\u003eNewtonite Mesh Plugs\u003c\/span\u003e have been manufactured specifically for securing \u003ca rel=\"noopener\" href=\"https:\/\/www.platinumchemicals.co.uk\/products\/newton-damp-proof-membrane-803-newtonite\" target=\"_blank\"\u003e\u003cstrong\u003eNewtonite Lath Mesh Membrane\u003c\/strong\u003e\u003c\/a\u003e to internal masonry walls, making them far more suitable than general-purpose plugs for Newton damp proofing membrane installations.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent Blue Plug Specification:\u003c\/strong\u003e The blue \u003cspan\u003eNewtonite Mesh Plug\u003c\/span\u003e replaces the previous brown version and should be treated as the current product specification, ensuring installations use the latest and most capable fixing design from Newton.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtended Plug Length: \u003c\/strong\u003eThe updated blue plug is approximately 10mm longer than the older brown plug, improving fixing stability and providing a stronger mechanical hold when correctly installed into suitable wall substrates.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSecure Membrane Anchorage:\u003c\/strong\u003e The plug holds the meshed membrane firmly against the wall, helping prevent sagging, drumming or movement before plaster, render or dry-lining finishes are applied.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuitable for Direct Plastering and Rendering Systems: \u003c\/strong\u003eWhen installed at 16 plugs per m², \u003cspan\u003eNewtonite Mesh Plugs\u003c\/span\u003e provide the close fixing pattern required to support direct plaster or render finishes over \u003ca rel=\"noopener\" href=\"https:\/\/www.platinumchemicals.co.uk\/products\/newton-damp-proof-membrane-803-newtonite\" target=\"_blank\"\u003e\u003cstrong\u003eNewtonite Lath Mesh Membrane\u003c\/strong\u003e\u003c\/a\u003e.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuitable for Dot and Dab Plasterboard:\u003c\/strong\u003e For dot and dab plasterboard installations, 10 plugs per m² is normally sufficient, making the fixing layout practical while still holding the membrane securely to the wall.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompatible with Newtonite 801 Mastic Sealing:\u003c\/strong\u003e In higher risk damp conditions, Newtonite 801 Mastic can be applied inside the plug head before fixing, helping to form a damp proof seal around the fixing point.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSupports Damp Separation from the Wall:\u003c\/strong\u003e By securing the membrane correctly, the plugs help create a physical separation between damp masonry and the new internal finish, reducing the risk of damp and salt contamination affecting the surface.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUseful in Refurbishment Work: \u003c\/strong\u003eNewton \u003cspan\u003eNewtonite Mesh Plugs\u003c\/span\u003e are well suited to renovation and remedial damp proofing projects, in situations where existing masonry walls need to be upgraded without relying solely on direct wall treatments.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimple 7mm SDS Installation: \u003c\/strong\u003eThe plug is installed using a 7mm SDS drill bit, giving a straightforward fixing method for trained installers working on Newtonite membrane systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eTypical Applications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNewtonite Damp Proofing System Installations: \u003c\/strong\u003eNewton \u003cspan\u003eNewtonite Mesh Plugs\u003c\/span\u003e are used to secure \u003ca rel=\"noopener\" href=\"https:\/\/www.platinumchemicals.co.uk\/products\/newton-damp-proof-membrane-803-newtonite\" target=\"_blank\"\u003e\u003cstrong\u003eNewtonite Lath Mesh Membrane\u003c\/strong\u003e\u003c\/a\u003e as part of Newton’s internal damp proofing system for walls affected by dampness or salt contamination.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInternal Above-Ground Damp Proofing: \u003c\/strong\u003eWell suited to above-ground damp proofing work where the objective is to separate the new plaster, render or dry-lining finish from residual damp within the wall.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFixing Newtonite Lath Mesh Membrane:\u003c\/strong\u003e The primary application is fixing Newton’s meshed damp proof membrane to masonry walls before direct plastering, rendering or dot and dab plasterboard installation.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDirect Plastering Over Membrane: \u003c\/strong\u003eUsed in situations where the meshed membrane will be finished directly with plaster, with a higher fixing density of 16 plugs per m² to hold the membrane securely under the applied finish.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDirect Rendering Over Membrane: \u003c\/strong\u003eWell suited to internal render systems where the mesh membrane needs close mechanical restraint to resist movement and provide a stable background for the render build-up.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDot and Dab Plasterboard Finishes:\u003c\/strong\u003e Used where plasterboard will be dot and dab fixed over the membrane, with a typical fixing density of 10 plugs per m² to secure the membrane before boarding.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDamp Wall Refurbishment: \u003c\/strong\u003eUseful in older properties where internal walls are affected by damp, salts or moisture staining, and where a membrane-based remedial finish is required rather than direct decoration.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSalt-Contaminated Masonry Walls:\u003c\/strong\u003e Well suited to situations where the membrane is used to isolate new finishes from salt-contaminated backgrounds, helping prevent staining and breakdown of the final decorative surface.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigher Risk Damp Areas with Mastic Sealing:\u003c\/strong\u003e In more demanding damp wall situations, the plugs can be used with Newtonite 801 Mastic to help seal around the plug head and improve protection at fixing points.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRenovation and Property Maintenance Work: \u003c\/strong\u003eAppropriate for damp proofing contractors, plasterers, builders and refurbishment specialists installing Newtonite mesh membranes in domestic and commercial properties.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eFAQ's\u003c\/h5\u003e\n\u003ch3\u003eQ) What are Newton \u003cspan\u003eNewtonite Mesh Plugs\u003c\/span\u003e and what are they designed for?\u003c\/h3\u003e\n\u003cp\u003eA) Newton \u003cspan\u003eNewtonite Mesh Plugs\u003c\/span\u003e (Newton product reference A16) are specialist fixing plugs designed for securing \u003ca rel=\"noopener\" href=\"https:\/\/www.platinumchemicals.co.uk\/products\/newton-damp-proof-membrane-803-newtonite\" target=\"_blank\"\u003e\u003cstrong\u003eNewtonite Lath Mesh Membrane\u003c\/strong\u003e\u003c\/a\u003e to internal masonry walls within the \u003ca href=\"https:\/\/www.platinumchemicals.co.uk\/collections\/newton-damp-proof-membrane\" target=\"_blank\" rel=\"noopener\"\u003e\u003cstrong\u003eNewtonite Damp Proofing System\u003c\/strong\u003e\u003c\/a\u003e. The current blue plug design replaces the older brown version and is approximately 10mm longer, providing improved fixing stability and enhanced performance. Installed through the meshed damp proofing membrane using a 7mm SDS drilled hole, the plug anchors the membrane securely against the substrate before plaster, render or dot and dab plasterboard finishes are applied. For direct plastering or rendering, 16 plugs per m² should be used. For dot and dab plasterboard, 10 plugs per m² is normally sufficient to hold the membrane correctly in position.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eQ) What is the difference between the blue and brown \u003cspan\u003eNewtonite Mesh Plugs\u003c\/span\u003e?\u003c\/h3\u003e\n\u003cp\u003eA) The blue \u003cspan\u003eNewtonite Mesh Plug\u003c\/span\u003e is the current product specification and replaces the older brown version, which is now superseded. The updated blue plug is approximately 10mm longer than the former brown design, providing improved fixing stability and a stronger mechanical hold when correctly installed into suitable wall substrates. This additional length helps the plug achieve better anchorage in masonry, which is particularly important when the membrane must be held firmly in position before plastering, rendering or dry-lining work begins. Any existing stock of brown \u003cspan\u003eNewtonite Mesh Plug\u003c\/span\u003e should be treated as the older generation product. When specifying or ordering Newton \u003cspan\u003eNewtonite Mesh Plugs\u003c\/span\u003e for Newtonite Damp Proofing System installations, the current blue plug is the correct version to use.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eQ) Where can \u003cspan\u003eNewtonite Mesh Plugs\u003c\/span\u003e be used in damp proofing work?\u003c\/h3\u003e\n\u003cp\u003eA) \u003cspan\u003eNewtonite Mesh Plugs\u003c\/span\u003e are designed for internal above-ground damp proofing applications within the Newton Newtonite Damp Proofing System. Their primary use is fixing Newtonite Lath Mesh Membrane to masonry walls before direct plastering, rendering or dot and dab plasterboard installation. They are well suited to older properties where internal walls are affected by residual moisture, hygroscopic salts or general dampness, and where a membrane-based remedial finish is required. Typical uses include direct plastering and rendering over membrane, dot and dab plasterboard finishes, damp wall refurbishment, salt-contaminated masonry wall treatment, higher risk damp areas with Newtonite 801 Mastic sealing, and general renovation and property maintenance work involving Newtonite meshed membranes in domestic and commercial properties.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eQ) When should \u003cspan\u003eNewtonite Mesh Plugs\u003c\/span\u003e be used with Newtonite 801 Mastic?\u003c\/h3\u003e\n\u003cp\u003eA) \u003cspan\u003eNewtonite Mesh Plugs\u003c\/span\u003e should be used with Newtonite 801 Mastic in higher risk or more demanding damp wall situations where additional protection around fixing penetrations is required. The mastic is applied to the inside of the plug head before the plug is fixed through the membrane into the wall, creating a damp proof seal around the plug head. This is particularly useful where the wall is subject to significant moisture, hygroscopic salt activity or residual damp that could potentially track through the fixing point. In standard above-ground damp proofing with lower risk conditions, the plugs can be installed without mastic sealing, but specifying mastic for the plug heads provides a more robust detail in challenging or high-moisture environments.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eQ) What are the main advantages of \u003cspan\u003eNewtonite Mesh Plugs\u003c\/span\u003e?\u003c\/h3\u003e\n\u003cp\u003eA) \u003cspan\u003eNewtonite Mesh Plugs\u003c\/span\u003e offer several practical advantages for Newtonite membrane installations. They are specifically manufactured for securing Newtonite Lath Mesh Membrane, making them far more suitable than general-purpose plugs for this application. The current blue plug is approximately 10mm longer than the previous version, improving fixing stability and mechanical hold. When installed at the correct density, they hold the membrane firmly against the wall, preventing sagging, drumming or movement before finishing work begins. They are suitable for both direct plaster and render systems at 16 plugs per m², and for dot and dab plasterboard at 10 plugs per m². They are also compatible with Newtonite 801 Mastic sealing for higher risk conditions, providing a damp proof seal around each fixing point.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eQ) How are \u003cspan\u003eNewtonite Mesh Plugs\u003c\/span\u003e installed correctly?\u003c\/h3\u003e\n\u003cp\u003eA) \u003cspan\u003eNewtonite Mesh Plugs\u003c\/span\u003e are installed using a 7mm SDS drill bit to create a clean, accurate fixing hole through the Newtonite Lath Mesh Membrane and into the masonry substrate. The membrane should be correctly positioned, levelled and aligned on the wall before drilling begins. The plug is then inserted through the membrane and driven into position to anchor it firmly against the wall. Where Newtonite 801 Mastic sealing is required, the mastic should be applied to the inside of the plug head before the plug is inserted, so that it compresses and seals around the fixing point as the plug is driven home. After installation, check each plug is secure, fully seated and holding the membrane evenly and tightly against the wall surface.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eQ) What fixing density is recommended for \u003cspan\u003eNewtonite Mesh Plugs\u003c\/span\u003e?\u003c\/h3\u003e\n\u003cp\u003eA) The recommended fixing density for \u003cspan\u003eNewtonite Mesh Plugs\u003c\/span\u003e depends on the type of internal finish being applied over the Newtonite Lath Mesh Membrane. For direct plastering or rendering, 16 \u003cspan\u003eNewtonite Mesh Plugs\u003c\/span\u003e per m² should be used to provide the close fixing pattern required to support the applied finish and prevent membrane movement. For dot and dab plasterboard installations, 10 plugs per m² is normally sufficient, as this finishing method imposes different support and fixing requirements compared with a wet plaster or render system. Correct plug spacing is genuinely important in both cases, as insufficient fixings can allow the membrane to sag, drum or move before and during the application of the wall finish.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eQ) Why is it important to use the correct fixing density for \u003cspan\u003eNewtonite Mesh Plugs\u003c\/span\u003e?\u003c\/h3\u003e\n\u003cp\u003eA) Using the correct fixing density for \u003cspan\u003eNewtonite Mesh Plugs\u003c\/span\u003e is critical because the membrane must be held firmly and evenly against the wall before any plaster, render or dry-lining finish is applied. If too few plugs are used, the Newtonite Lath Mesh Membrane can sag between fixing points, drum when tapped, or move during the application of wet finishes. This can result in an uneven background, poor adhesion of the plaster or render, and a finish that may crack or fail in service. The fixing density also affects how well the membrane performs its damp separating function, as a membrane that is not tight to the wall may allow bridging of moisture between the masonry and the new finish.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eQ) What is the role of Newtonite Lath Mesh Membrane in the system?\u003c\/h3\u003e\n\u003cp\u003eA) Newtonite Lath Mesh Membrane is a BBA Approved meshed damp proof membrane that forms the core of Newton’s Newtonite Damp Proofing System. Its primary role is to create a physical moisture-resistant separating layer between damp or salt-contaminated masonry and the new internal finish. Rather than attempting to stop water within the wall, the membrane provides a managed separation that prevents residual moisture and hygroscopic salts from reaching and damaging the new plaster, render or dry-lining. The mesh face provides a suitable key for direct plaster, render or compatible finishing systems. \u003cspan\u003eNewtonite Mesh Plugs\u003c\/span\u003e are essential to this system because they hold the membrane tight and evenly against the wall, ensuring the separation layer performs correctly throughout the life of the installation.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eQ) What substrates are \u003cspan\u003eNewtonite Mesh Plugs\u003c\/span\u003e suitable for?\u003c\/h3\u003e\n\u003cp\u003eA) \u003cspan\u003eNewtonite Mesh Plugs\u003c\/span\u003e are designed for fixing Newtonite Lath Mesh Membrane to internal masonry walls that are sound enough to accept a 7mm SDS drilled fixing. Suitable substrates include brick, stone, blockwork and concrete walls commonly found in older and traditionally constructed domestic and commercial properties. The masonry should be stable and capable of holding the plug securely. Where walls are loose, crumbling or severely deteriorated, localised repairs should be carried out before membrane installation begins to ensure the fixings can achieve adequate hold. In higher risk or more damp masonry situations, the plugs should be used with Newtonite 801 Mastic to seal around the plug head and improve the damp proofing detail at each fixing penetration.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eQ) Are there practical tips for getting the best results when installing \u003cspan\u003eNewtonite Mesh Plugs\u003c\/span\u003e?\u003c\/h3\u003e\n\u003cp\u003eA) For the best results when installing \u003cspan\u003eNewtonite Mesh Plugs\u003c\/span\u003e, ensure the Newtonite Lath Mesh Membrane is correctly positioned and aligned on the wall before drilling begins. Use a 7mm SDS drill bit to form clean, straight holes through the membrane and into the masonry, avoiding tearing or enlarging the membrane around each fixing point. Apply the correct fixing density from the outset, using 16 plugs per m² for direct plaster or render systems and 10 plugs per m² for dot and dab plasterboard. Where higher risk damp conditions are present, apply Newtonite 801 Mastic to the plug head before installation. After fixing, check each plug is fully seated and the membrane is held tightly and evenly across the full wall area before finishing begins.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eQ) What are the limitations of \u003cspan\u003eNewtonite Mesh Plugs\u003c\/span\u003e?\u003c\/h3\u003e\n\u003cp\u003eA) \u003cspan\u003eNewtonite Mesh Plugs\u003c\/span\u003e have several important limitations to be aware of. They are specifically designed for securing Newtonite Lath Mesh Membrane within the Newton Newtonite Damp Proofing System and are not suitable for general-purpose fixing applications. The current specification is the blue plug, and the older brown version should no longer be used in new installations. The plugs rely on a sound masonry substrate to achieve adequate mechanical hold, so loose, crumbling or severely deteriorated walls must be repaired before installation. Insufficient fixing density, incorrect drill hole size or plugs that are not fully seated can all compromise membrane performance. In high-risk damp conditions, Newtonite 801 Mastic should be used with the plug heads to provide adequate sealing around each fixing penetration.\u003cbr\u003e\u003c\/p\u003e","brand":"John Newton \u0026 Co. Ltd","offers":[{"title":"(W) 8mm x (L) 60mm \/ Bag of 200","offer_id":40057906626659,"sku":"NA16NEW","price":28.5,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2617\/5036\/files\/newton-newtonite-mesh-plugs-w-8mm-x-l-60mm-bag-of-200-damp-proof-membrane-ancillaries-485.webp?v=1780488008","url":"https:\/\/www.platinumchemicals.co.uk\/products\/newton-newtonite-mesh-plugs-damp-proof-membrane-fixing","provider":"Platinum Chemicals","version":"1.0","type":"link"}