{"product_id":"newton-newtonite-lath-meshed-damp-proof-membrane-kit","title":"Newton Newtonite LATH Damp Proof Membrane Kit (With Fixings \u0026 Sealing Mastic)","description":"\u003cp\u003eNewton Newtonite Lath Meshed Damp Proof Membrane Kits combine the meshed membrane with Newtonite Mesh Plugs, Newtonite 801 Mastic Sealant and SDS Plus masonry drill bits. Designed for above-ground damp proofing, the kits provide a practical starting point for separating new internal finishes from damp and salts within suitable walls.\u003c\/p\u003e\n\u003cp\u003eThe 0.5mm HDPE sheet has raised 3mm studs and a heat-welded polythene mesh. Studs face the wall to support vapour equalisation, while the room-facing mesh creates a mechanical key for suitable plaster, render, hydraulic lime or dot-and-dab plasterboard.\u003c\/p\u003e\n\u003cp\u003eChoose from 10m², 12m², 20m² and 40m² kit formats, using 1m x 10m, 1.2m x 10m, 1m x 20m and 2m x 20m membrane rolls respectively. The included 60mm plugs and mastic support sealed mechanical fixing, and the membrane can be cut and installed horizontally or vertically to suit the wall layout.\u003cbr\u003e\u003c\/p\u003e\n\u003ch5\u003eDescription\u003c\/h5\u003e\n\u003ch2\u003e\u003cstrong\u003eKey Features Of Newton Newtonite Lath Membrane Kits\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cbr\u003e✔️ Four kit options combine Newtonite Lath membrane, Mesh Plugs, 801 Mastic Sealant and SDS Plus drill bits.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e✔️ Nominal membrane coverage of 10m², 12m², 20m² or 40m² suits measured above-ground wall refurbishment areas.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e✔️ Heat-welded mesh provides a mechanical key for specified plaster, render, hydraulic lime and dot-and-dab plasterboard.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e✔️ Low-profile construction combines a 0.5mm HDPE sheet with raised 3mm studs for vapour equalisation.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e✔️ Supplied Newtonite Mesh Plugs and 801 Mastic provide a purpose-matched arrangement for sealed fixing to suitable masonry.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: rgb(88, 88, 88);\"\u003eMeshed Membrane Kits For Above-Ground Damp Proofing\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eNewton Newtonite Lath Meshed Damp Proof Membrane Kits bring together the principal membrane, fixing, sealing-mastic and drilling components for suitable above-ground wall refurbishment. Their core component is a meshed HDPE sheet designed to isolate new internal finishes from dampness and salts within the background. The raised 3mm studs face the wall, creating channels for vapour equalisation, while the heat-welded mesh faces the room to receive the specified finish. The membrane is intended for non-earth-retaining walls and does not require an intentionally ventilated gap at its upper or lower edge. Suitable work includes correctly assessed rising-damp refurbishment and salt-contaminated internal masonry. Diagnose the moisture source and address practical building defects before enclosing the wall. The kit supports the installation of the damp-proof separation layer; the supporting structure and selected finish must also be suitable for the project.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: rgb(88, 88, 88);\"\u003eMatched Newtonite Fixings, Mastic And Drill Bits\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eEach kit includes Newtonite Mesh Plugs for securing the membrane to suitable internal masonry, Newtonite 801 Mastic Sealant for sealing fixing penetrations and SDS Plus masonry drill bits for forming the holes. The recommended plugs are 60mm long and use a 8mm drilled hole, with a drilling depth of at least 60mm plus the additional clearance needed for debris so the plug seats fully. Mastic is applied around each hole before the plug is driven home, maintaining separation between the damp background and the new finish. The supplied plug, cartridge and drill-bit quantities vary with the kit size and are set out in the contents table. These components work with the membrane's keyed finishing surface to provide secure support for the chosen plaster, render or dot-and-dab plasterboard arrangement. Select the final finish before marking out the fixing positions.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: rgb(88, 88, 88);\"\u003eFour Kit Sizes For Measured Refurbishment Areas\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eFour kit formats allow the membrane roll to be selected around the size of the wall-treatment area and the practicalities of handling. The 10m² kit uses a 1m x 10m roll, the 12m² kit a 1.2m x 10m roll, the 20m² kit a 1m x 20m roll and the 40m² kit a 2m x 20m roll. Each includes the corresponding fixed quantities of Mesh Plugs, 801 Mastic and drill bits shown below. Nominal kit area is the full uncut membrane area, so measure return walls, reveals and other details as well as the main elevation. Horizontal or vertical fitting can help coordinate the sheet layout with wall height and opening positions. Smaller rolls suit restricted handling conditions, while the wider format can reduce vertical joints across larger wall sections. The complete build-up also includes the specified internal finish.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: rgb(88, 88, 88);\"\u003eCompatible With Plaster, Render And Dot-And-Dab Plasterboard\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eThe heat-welded polythene mesh provides a mechanical key for suitable plaster, cement\/lime render, natural hydraulic lime and proprietary plasterboard adhesive. This allows the selected finish to engage with the membrane surface while the HDPE separates it from dampness and salts within the background. Newton recommends Tarmac Whitewall One Coat Plaster in two separate 6mm coats over Newtonite Lath, rather than a single application. Traditional cement\/lime render uses its own two-coat specification, while the hydraulic lime option uses two 10mm coats. Dot-and-dab plasterboard requires the specified adhesive coverage and any necessary board restraint. Fixing quantities depend on the chosen finish: use 16plugs\/m² for direct plaster or render and 10plugs\/m² for dot-and-dab plasterboard. Plan the finish before installation so membrane support, coat thickness, curing time and details around floors, openings and services are properly coordinated.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: rgb(88, 88, 88);\"\u003eSimple Installation With Sealed Fixings And Butt Joints\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eNewtonite Lath can be cut with a sharp utility knife, scissors or shears and fitted horizontally or vertically to suit the wall layout. Remove unstable plaster and defective render, retaining sound existing render where it remains suitable for dependable mechanical fixing. Position the sheet with studs towards the wall and mesh towards the room, keeping it taut, square and free from sagging. The supplied Mesh Plugs secure it to suitable masonry, with 801 Mastic sealing the fixing penetrations. Adjoining edges form close butt joints sealed centrally with separately supplied Newton Mesh Tape, retaining a keyed surface across each joint. Continue the damp-proof separation around corners, onto return walls and into reveals as specified. Plan service openings and seal them before finishing, then inspect the membrane, fixings and joints before they become concealed beneath the chosen wall surface.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: rgb(88, 88, 88);\"\u003eLong-Term Membrane Protection For Refurbishment Projects\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eNewtonite Lath is manufactured from HDPE with a rot-proof mesh and is resistant to water, salts, alkalis and biological degradation within its intended application. Published membrane performance includes an Sd value above 604m, thermal conductivity of 0.461W\/mK and Euroclass E reaction to fire. The complete wall finish must meet the requirements of the building and protect the membrane during service. Newton guarantees the membrane against deterioration for 30 years and gives a published life expectancy of at least 50 years, subject to the applicable installation, protection and service conditions. These statements apply to the membrane only, not the complete kit. Secure anchorage, properly sealed penetrations, firmly bonded joints and correctly cured finishes all contribute to the completed installation. Later services and wall fittings must use planned, sealed penetrations rather than uncontrolled drilling through the damp-proof layer.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cstyle\u003e\n  .pc-newton-newtonite-lath-kit-table-swipe {\n    display: none;\n    margin: 0 0 6px;\n    color: #555;\n    font: 600 13px\/1.3 inherit;\n  }\n\n  .pc-newton-newtonite-lath-kit-table-wrap {\n    width: 100%;\n    max-width: 100%;\n    margin: 24px 0;\n    position: relative;\n    overflow-x: visible;\n  }\n\n  .pc-newton-newtonite-lath-kit-table {\n    width: 100%;\n    max-width: 100%;\n    min-width: 0;\n    table-layout: fixed;\n    border-collapse: collapse;\n    font-family: inherit;\n    font-size: 16px;\n    line-height: 1.35;\n    color: #111;\n    background: #fff;\n  }\n\n  .pc-newton-newtonite-lath-kit-table th,\n  .pc-newton-newtonite-lath-kit-table td {\n    border: 5px solid #fff;\n    padding: 9px 12px;\n    vertical-align: top;\n    text-align: left;\n    font-weight: 400;\n    overflow-wrap: anywhere;\n  }\n\n  .pc-newton-newtonite-lath-kit-table .pc-main-title {\n    padding: 14px 18px;\n    background: #7f7f7f;\n    color: #fff;\n    text-align: center;\n    text-transform: uppercase;\n    font-size: 30px;\n    line-height: 1.15;\n    font-weight: 700;\n  }\n\n  .pc-newton-newtonite-lath-kit-table .pc-column-head {\n    background: #a6a6a6;\n    color: #111;\n    text-align: left;\n    font-size: 18px;\n    line-height: 1.25;\n    font-weight: 700;\n  }\n\n  .pc-newton-newtonite-lath-kit-table .pc-data-row {\n    background: #fff;\n  }\n\n  .pc-newton-newtonite-lath-kit-table .pc-data-row.pc-grey {\n    background: #d9d9d9;\n  }\n\n  .pc-newton-newtonite-lath-kit-table .pc-kit-size-cell {\n    color: #111;\n    text-align: left;\n    font-weight: 700;\n  }\n\n  @media screen and (max-width: 767px), (hover: none) and (pointer: coarse) {\n    .pc-newton-newtonite-lath-kit-table-swipe {\n      display: block;\n    }\n\n    .pc-newton-newtonite-lath-kit-table-wrap {\n      overflow-x: auto;\n      -webkit-overflow-scrolling: touch;\n    }\n\n    .pc-newton-newtonite-lath-kit-table {\n      min-width: 900px;\n      font-size: 14px;\n    }\n\n    .pc-newton-newtonite-lath-kit-table th,\n    .pc-newton-newtonite-lath-kit-table td {\n      border-width: 4px;\n      padding: 7px 9px;\n    }\n\n    .pc-newton-newtonite-lath-kit-table .pc-main-title {\n      padding: 11px 13px;\n      font-size: 23px;\n    }\n\n    .pc-newton-newtonite-lath-kit-table .pc-column-head {\n      font-size: 16px;\n    }\n  }\n\u003c\/style\u003e\n\u003cp class=\"pc-newton-newtonite-lath-kit-table-swipe\" aria-hidden=\"true\"\u003eSwipe horizontally to view the full table →\u003c\/p\u003e\n\u003cdiv class=\"pc-newton-newtonite-lath-kit-table-wrap\" role=\"region\" aria-label=\"Newton Newtonite Lath membrane kit contents table\"\u003e\n\u003ctable class=\"pc-newton-newtonite-lath-kit-table\" aria-label=\"Newton Newtonite Lath Meshed Damp Proof Membrane Kit Contents\"\u003e\n\u003ccolgroup\u003e \u003ccol style=\"width: 11%;\"\u003e \u003ccol style=\"width: 23%;\"\u003e \u003ccol style=\"width: 22%;\"\u003e \u003ccol style=\"width: 22%;\"\u003e \u003ccol style=\"width: 22%;\"\u003e \u003c\/colgroup\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"pc-main-title\" colspan=\"5\" scope=\"colgroup\"\u003eNewton Newtonite Lath Meshed Damp Proof Membrane Kit Contents\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"pc-column-head\" scope=\"col\"\u003eKit Size\u003c\/th\u003e\n\u003cth class=\"pc-column-head\" scope=\"col\"\u003eNewtonite Lath Membrane Roll\u003c\/th\u003e\n\u003cth class=\"pc-column-head\" scope=\"col\"\u003eNewtonite Mesh Plugs\u003c\/th\u003e\n\u003cth class=\"pc-column-head\" scope=\"col\"\u003eNewtonite 801 Mastic Sealant\u003c\/th\u003e\n\u003cth class=\"pc-column-head\" scope=\"col\"\u003e8mm x 160mm SDS Plus Drill Bits\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr class=\"pc-data-row\"\u003e\n\u003cth class=\"pc-kit-size-cell\" scope=\"row\"\u003e10m² Kit\u003c\/th\u003e\n\u003ctd\u003e1 x 1m x 10m roll\u003c\/td\u003e\n\u003ctd\u003e160 plugs\u003c\/td\u003e\n\u003ctd\u003e2 cartridges\u003c\/td\u003e\n\u003ctd\u003e1 bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row pc-grey\"\u003e\n\u003cth class=\"pc-kit-size-cell\" scope=\"row\"\u003e12m² Kit\u003c\/th\u003e\n\u003ctd\u003e1 x 1.2m x 10m roll\u003c\/td\u003e\n\u003ctd\u003e200 plugs\u003c\/td\u003e\n\u003ctd\u003e2 cartridges\u003c\/td\u003e\n\u003ctd\u003e1 bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row\"\u003e\n\u003cth class=\"pc-kit-size-cell\" scope=\"row\"\u003e20m² Kit\u003c\/th\u003e\n\u003ctd\u003e1 x 1m x 20m roll\u003c\/td\u003e\n\u003ctd\u003e320 plugs\u003c\/td\u003e\n\u003ctd\u003e3 cartridges\u003c\/td\u003e\n\u003ctd\u003e2 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row pc-grey\"\u003e\n\u003cth class=\"pc-kit-size-cell\" scope=\"row\"\u003e40m² Kit\u003c\/th\u003e\n\u003ctd\u003e1 x 2m x 20m roll\u003c\/td\u003e\n\u003ctd\u003e650 plugs\u003c\/td\u003e\n\u003ctd\u003e4 cartridges\u003c\/td\u003e\n\u003ctd\u003e2 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003eKit areas are nominal membrane coverage before cutting and site waste. The quantities shown are the contents supplied with each kit.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2617\/5036\/files\/Newtonite_Lath_1_1024x1024.png?v=1793882668\" alt=\"\" style=\"float: none;\"\u003e\u003c\/div\u003e\n\u003ch6 style=\"text-align: center;\"\u003e\n\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eSecure fixings and taped joints help Newtonite Lath form a continuous barrier against damp and salts behind new wall finishes.\u003c\/strong\u003e\u003c\/em\u003e\n\u003c\/h6\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eChoosing The Correct Kit And Additional Components\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eMeasure the main wall, return walls, reveals and other areas receiving the membrane, allowing for trimming, openings and site waste. Choose the roll width and sheet orientation to suit the wall height and access. Nominal kit coverage is the uncut roll area, rather than guaranteed finished wall coverage.\u003c\/p\u003e\n\u003cp\u003eCalculate fixing requirements using 16plugs\/m² for direct plaster or render and 10plugs\/m² for dot-and-dab plasterboard, adding local support where necessary around edges, openings and difficult backgrounds. The four kits contain 160, 200, 320 or 650 Mesh Plugs respectively. Newtonite Cob Plugs are selected separately where suitable slightly friable mortar requires the expanding fixing arrangement.\u003c\/p\u003e\n\u003cp\u003eNewton Mesh Tape is supplied separately. Measure the total length of close butt joints, corner cuts, reveals and repairs before ordering tape. The kits include Newtonite 801 Mastic for fixing seals and compatible penetrations; calculate any additional cartridge requirement from the actual detail layout.\u003c\/p\u003e\n\u003cp\u003eSelect the plaster, render, hydraulic lime, plasterboard adhesive, boards and any finishing profiles for the intended wall finish. Where diagnosis identifies a separate remedial treatment, complete it as specified before the membrane is concealed.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eProduct Benefits\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDamp And Salt Separation:\u003c\/strong\u003e Isolates suitable new internal finishes from damp masonry and associated salts, helping prevent moisture-related staining and deterioration of the finished wall surface.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegral Finishing Key: \u003c\/strong\u003eHeat-welded polythene mesh provides a mechanical key for compatible plaster, render and plasterboard adhesive, allowing the selected finish to engage with the membrane surface.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLow-Profile Wall Treatment:\u003c\/strong\u003e The shallow 3mm stud pattern limits the space occupied by the membrane, helping retain usable room width during internal wall refurbishment and renovation.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFour Kit Options: \u003c\/strong\u003eMembrane rolls and corresponding installation components are supplied in four practical formats, helping coordinate ordering with wall dimensions and the extent of refurbishment work.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eReduced Render Removal: \u003c\/strong\u003eFirmly bonded existing render can remain where suitable, reducing unnecessary removal work while loose, detached or otherwise unsuitable background materials are removed or repaired.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVapour Equalisation Channels: \u003c\/strong\u003eStuds facing the wall create narrow channels behind the membrane, supporting vapour equalisation without requiring an intentionally ventilated gap around the treated wall perimeter.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChoice Of Internal Finishes: \u003c\/strong\u003eSuitable specifications include plaster, cement\/lime render, natural hydraulic lime and dot-and-dab plasterboard, allowing the wall finish to suit the particular refurbishment project.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Sheet Orientation: \u003c\/strong\u003eCan be installed horizontally or vertically, allowing the layout to accommodate wall height, available working space, joint positions, return walls and window or door reveals.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIncluded Drilling Components:\u003c\/strong\u003e Each kit contains one or two 8mm x 160mm SDS Plus masonry drill bits for forming holes for the recommended Newtonite Mesh Plugs.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIncluded Newtonite Fixings: \u003c\/strong\u003eThe supplied 60mm Mesh Plugs secure the membrane to suitable masonry, with included 801 Mastic sealing fixing penetrations against dampness and salt bridging.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eKeyed Joint Sealing: \u003c\/strong\u003eNewton Mesh Tape face-seals close butt joints while retaining a textured surface, allowing the specified plaster or render finish to continue across adjoining membrane sheets.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUseful Return-Wall Detailing: \u003c\/strong\u003eThe membrane can continue onto return walls and into reveals, helping maintain separation where dampness might otherwise affect finishes beside the main treated area.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eResistance To Damp-Wall Conditions:\u003c\/strong\u003e HDPE construction resists water, salts, alkalis and biological degradation, supporting durable separation behind a correctly installed and protected internal wall finishing system.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Membrane Protection: \u003c\/strong\u003eNewton guarantees the membrane against deterioration for 30 years and gives a life expectancy of at least 50 years, subject to installation and service conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eTypical Applications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAbove-Ground Damp Walls: \u003c\/strong\u003eProvides a base for suitable new internal finishes on damp, non-earth-retaining walls where the moisture source and condition of the background have been assessed.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRising Damp Refurbishment:\u003c\/strong\u003e Isolates the internal finish on walls affected by diagnosed rising damp, forming part of the selected remedial specification and any separately required damp-proofing treatment.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSalt-Contaminated Masonry: \u003c\/strong\u003eSeparates new plaster, render or bonded plasterboard finishes from salts within existing masonry that could otherwise cause staining or deterioration of the finished surface.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDirect Plaster Finishes:\u003c\/strong\u003e Provides a meshed base for the specified two-coat plaster system, with sealed fixing points, taped butt joints and the required clearance above floor level.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInternal Cement\/Lime Render: \u003c\/strong\u003eSupports the specified two-coat render arrangement on suitable above-ground walls, using controlled coat thicknesses and curing to produce a stable internal finishing surface.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNatural Hydraulic Lime Finishes:\u003c\/strong\u003e Provides a mechanical key for the specified NHL3.5 and sand system, applied in separate coats with the required protection, setting intervals and tending.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDot-And-Dab Plasterboard: \u003c\/strong\u003eSuitable for proprietary plasterboard adhesive arrangements over the meshed face, with adhesive distributed across the membrane, plug heads and board edges to the specified coverage.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSound Existing Render: \u003c\/strong\u003eCan be fitted over firmly bonded render where the background remains suitable for secure mechanical fixing and any loose or defective areas have been repaired.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eReturn Walls And Reveals: \u003c\/strong\u003eSuitable for extending the damp-proof separation onto adjoining return walls and into window or door reveals, with corners and joints carefully formed and sealed.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLocalised Or Larger Renovations: \u003c\/strong\u003eFour kit formats suit measured wall-treatment areas, combining the selected membrane roll with fixing plugs, sealing mastic and drill bits for installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eStandards \u0026amp; Certificates\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBS EN 13967:2012+A1:2017: \u003c\/strong\u003eThe harmonised specification covers the declared damp-proof sheet application and associated essential characteristics. Use Newtonite Lath within its above-ground, non-earth-retaining installation scope.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBS EN 13501-1 Reaction To Fire: \u003c\/strong\u003eThe membrane is classified as Euroclass E. The fire performance of the completed wall depends on the complete construction and specified protective finish.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBS EN 1931 Water-Vapour Testing:\u003c\/strong\u003e Technical data records an Sd value above 604m, a calculated water-vapour resistance factor above 1,208,000 and water-vapour resistance above 3020MNs\/g.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer Guarantee And Life Expectancy: \u003c\/strong\u003eNewton guarantees Newtonite Lath against deterioration for 30 years and gives a life expectancy of at least 50 years, subject to the applicable installation, protection and service conditions. These statements apply to the membrane only, not the complete kit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eProduct Performance\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe technical values below apply to the Newtonite Lath membrane supplied with the kit. Newtonite Lath separates the chosen wall finish from dampness and salts within the substrate. The studs face the wall, while the heat-welded mesh faces the room and provides the mechanical key needed for the specified plaster, render or plasterboard adhesive. The studded space supports vapour equalisation and is not intended to be deliberately ventilated at the top or bottom.\u003c\/p\u003e\n\u003cp\u003eThe membrane has a 0.5mm sheet thickness, a 3mm stud pattern and a unit weight of 505g\/m². Technical data records a thickness of 2.64mm under 100kPa loading, thermal conductivity of 0.461W\/mK and a service-temperature range of -50°C to +80°C. The fixing application range is different: do not install fixings below -5°C or above +30°C.\u003c\/p\u003e\n\u003cp\u003ePublished water-vapour performance includes an Sd value above 604m, a calculated resistance factor above 1,208,000 and resistance above 3020MNs\/g. Chemical and oxidation resistance are both rated excellent, with reported results of 100% under the respective test methods. These properties do not remove the need to diagnose and appropriately treat unsuitable or contaminated backgrounds.\u003c\/p\u003e\n\u003cp\u003eThe Declaration of Performance records a pass for watertightness at 60kPa for 24 hours, compressive strength of 250kN and Euroclass E reaction to fire. These are membrane characteristics. Newtonite Lath remains restricted to above-ground, non-earth-retaining walls and must not be specified for groundwater ingress or hydrostatic pressure.\u003c\/p\u003e\n\u003cp\u003eFinishing performance depends on the selected material, fixing pattern and application method. Use 16plugs\/m² for direct plaster or render and 10plugs\/m² for dot-and-dab plasterboard, with additional support where the layout or substrate requires it. Maintain properly sealed fixings, close butt joints sealed with Newton Mesh Tape and the specified curing conditions before decoration.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cstyle\u003e\n  .pc-newton-newtonite-lath-tech-table-swipe {\n    display: none;\n    margin: 0 0 6px;\n    color: #555;\n    font: 600 13px\/1.3 inherit;\n  }\n\n  .pc-newton-newtonite-lath-tech-table-wrap {\n    width: 100%;\n    max-width: 100%;\n    overflow-x: visible;\n    margin: 24px 0;\n    position: relative;\n  }\n\n  .pc-newton-newtonite-lath-tech-table {\n    width: 100%;\n    max-width: 100%;\n    min-width: 0;\n    table-layout: fixed;\n    border-collapse: collapse;\n    font-family: inherit;\n    font-size: 16px;\n    line-height: 1.35;\n    color: #111;\n    background: #fff;\n  }\n\n  .pc-newton-newtonite-lath-tech-table th,\n  .pc-newton-newtonite-lath-tech-table td {\n    border: 5px solid #fff;\n    padding: 9px 12px;\n    vertical-align: top;\n    text-align: left;\n    font-weight: 400;\n    overflow-wrap: anywhere;\n  }\n\n  .pc-newton-newtonite-lath-tech-table .pc-main-title {\n    padding: 14px 18px;\n    background: #7f7f7f;\n    color: #fff;\n    text-align: center;\n    text-transform: uppercase;\n    font-size: 30px;\n    line-height: 1.15;\n    font-weight: 700;\n  }\n\n  .pc-newton-newtonite-lath-tech-table .pc-section-title {\n    padding: 11px 12px;\n    background: #8f8f8f;\n    color: #fff;\n    text-align: left;\n    font-size: 22px;\n    line-height: 1.2;\n    font-weight: 700;\n  }\n\n  .pc-newton-newtonite-lath-tech-table .pc-column-head {\n    background: #a6a6a6;\n    color: #111;\n    text-align: left;\n    font-size: 18px;\n    line-height: 1.25;\n    font-weight: 700;\n  }\n\n  .pc-newton-newtonite-lath-tech-table .pc-data-row {\n    background: #fff;\n  }\n\n  .pc-newton-newtonite-lath-tech-table .pc-data-row.pc-grey {\n    background: #d9d9d9;\n  }\n\n  .pc-newton-newtonite-lath-tech-table .pc-feature-cell {\n    color: #111;\n    text-align: left;\n    font-weight: 700;\n  }\n\n  .pc-newton-newtonite-lath-tech-table .pc-table-note {\n    padding: 10px 12px;\n    background: #f2f2f2;\n    color: #222;\n    font-size: 15px;\n    line-height: 1.4;\n    font-weight: 400;\n  }\n\n  @media screen and (max-width: 767px), (hover: none) and (pointer: coarse) {\n    .pc-newton-newtonite-lath-tech-table-swipe {\n      display: block;\n    }\n\n    .pc-newton-newtonite-lath-tech-table-wrap {\n      overflow-x: auto;\n      -webkit-overflow-scrolling: touch;\n    }\n\n    .pc-newton-newtonite-lath-tech-table {\n      min-width: 820px;\n      font-size: 14px;\n    }\n\n    .pc-newton-newtonite-lath-tech-table th,\n    .pc-newton-newtonite-lath-tech-table td {\n      border-width: 4px;\n      padding: 7px 9px;\n    }\n\n    .pc-newton-newtonite-lath-tech-table .pc-main-title {\n      padding: 11px 13px;\n      font-size: 23px;\n    }\n\n    .pc-newton-newtonite-lath-tech-table .pc-section-title {\n      padding: 9px;\n      font-size: 18px;\n    }\n\n    .pc-newton-newtonite-lath-tech-table .pc-column-head {\n      font-size: 16px;\n    }\n\n    .pc-newton-newtonite-lath-tech-table .pc-table-note {\n      font-size: 14px;\n    }\n  }\n\u003c\/style\u003e\n\u003cp class=\"pc-newton-newtonite-lath-tech-table-swipe\" aria-hidden=\"true\"\u003eSwipe horizontally to view the full table →\u003c\/p\u003e\n\u003cdiv class=\"pc-newton-newtonite-lath-tech-table-wrap\" role=\"region\" aria-label=\"Newton Newtonite Lath membrane kit technical data table\"\u003e\n\u003ctable class=\"pc-newton-newtonite-lath-tech-table\" aria-label=\"Newton Newtonite Lath Membrane Kit Technical Data\"\u003e\n\u003ccolgroup\u003e \u003ccol style=\"width: 36%;\"\u003e \u003ccol style=\"width: 18%;\"\u003e \u003ccol style=\"width: 22%;\"\u003e \u003ccol style=\"width: 24%;\"\u003e \u003c\/colgroup\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"pc-main-title\" colspan=\"4\" scope=\"colgroup\"\u003eNewton Newtonite Lath Membrane Kit Technical Data\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth class=\"pc-section-title\" colspan=\"4\" scope=\"colgroup\"\u003eTechnical Data\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"pc-table-note\" colspan=\"4\"\u003eThe following data applies to the Newtonite Lath membrane supplied with the kit. Packaged roll weights exclude the other kit components.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"pc-column-head\" colspan=\"2\" scope=\"col\"\u003eFeature\u003c\/th\u003e\n\u003cth class=\"pc-column-head\" scope=\"col\"\u003eResult\u003c\/th\u003e\n\u003cth class=\"pc-column-head\" scope=\"col\"\u003eTest Standard\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row\"\u003e\n\u003cth class=\"pc-feature-cell\" colspan=\"2\" scope=\"row\"\u003eProduct Type\u003c\/th\u003e\n\u003ctd\u003eMeshed damp-proof membrane for above-ground internal walls\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row pc-grey\"\u003e\n\u003cth class=\"pc-feature-cell\" colspan=\"2\" scope=\"row\"\u003eMembrane Material\u003c\/th\u003e\n\u003ctd\u003eHigh-density polyethylene (HDPE)\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row\"\u003e\n\u003cth class=\"pc-feature-cell\" colspan=\"2\" scope=\"row\"\u003eMesh Construction\u003c\/th\u003e\n\u003ctd\u003eRot-proof polythene mesh heat-welded to one face\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row pc-grey\"\u003e\n\u003cth class=\"pc-feature-cell\" colspan=\"2\" scope=\"row\"\u003eUnit Weight\u003c\/th\u003e\n\u003ctd\u003e505g\/m²\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row\"\u003e\n\u003cth class=\"pc-feature-cell\" colspan=\"2\" scope=\"row\"\u003eMembrane Sheet Thickness\u003c\/th\u003e\n\u003ctd\u003e0.5mm\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row pc-grey\"\u003e\n\u003cth class=\"pc-feature-cell\" colspan=\"2\" scope=\"row\"\u003eStud Depth\u003c\/th\u003e\n\u003ctd\u003e3mm\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row\"\u003e\n\u003cth class=\"pc-feature-cell\" colspan=\"2\" scope=\"row\"\u003eNominal Profile Height\u003c\/th\u003e\n\u003ctd\u003e3mm\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row pc-grey\"\u003e\n\u003cth class=\"pc-feature-cell\" colspan=\"2\" scope=\"row\"\u003eThickness At 100kPa\u003c\/th\u003e\n\u003ctd\u003e2.64mm\u003c\/td\u003e\n\u003ctd\u003eEN ISO 25619-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row\"\u003e\n\u003cth class=\"pc-feature-cell\" colspan=\"2\" scope=\"row\"\u003eVicat Softening Temperature\u003c\/th\u003e\n\u003ctd\u003e126°C\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row pc-grey\"\u003e\n\u003cth class=\"pc-feature-cell\" colspan=\"2\" scope=\"row\"\u003eService Temperature\u003c\/th\u003e\n\u003ctd\u003e-50°C to +80°C\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row\"\u003e\n\u003cth class=\"pc-feature-cell\" colspan=\"2\" scope=\"row\"\u003eFixing Application Temperature\u003c\/th\u003e\n\u003ctd\u003e-5°C to +30°C\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row pc-grey\"\u003e\n\u003cth class=\"pc-feature-cell\" colspan=\"2\" scope=\"row\"\u003eThermal Conductivity\u003c\/th\u003e\n\u003ctd\u003e0.461W\/mK\u003c\/td\u003e\n\u003ctd\u003eEN 12667\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row\"\u003e\n\u003cth class=\"pc-feature-cell\" colspan=\"2\" scope=\"row\"\u003eWater-Vapour Diffusion Resistance - Sd Value\u003c\/th\u003e\n\u003ctd\u003e\u0026gt;604m\u003c\/td\u003e\n\u003ctd\u003eBS EN 1931\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row pc-grey\"\u003e\n\u003cth class=\"pc-feature-cell\" colspan=\"2\" scope=\"row\"\u003eWater-Vapour Resistance Factor - µ Value\u003c\/th\u003e\n\u003ctd\u003e\u0026gt;1,208,000\u003c\/td\u003e\n\u003ctd\u003eCalculated from Sd value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row\"\u003e\n\u003cth class=\"pc-feature-cell\" colspan=\"2\" scope=\"row\"\u003eWater-Vapour Resistance\u003c\/th\u003e\n\u003ctd\u003e\u0026gt;3020MNs\/g\u003c\/td\u003e\n\u003ctd\u003eCalculated from Sd value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row pc-grey\"\u003e\n\u003cth class=\"pc-feature-cell\" colspan=\"2\" scope=\"row\"\u003eReaction To Fire\u003c\/th\u003e\n\u003ctd\u003eEuroclass E\u003c\/td\u003e\n\u003ctd\u003eBS EN 13501-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row\"\u003e\n\u003cth class=\"pc-feature-cell\" colspan=\"2\" scope=\"row\"\u003eChemical Resistance\u003c\/th\u003e\n\u003ctd\u003eExcellent - 100%\u003c\/td\u003e\n\u003ctd\u003eEN 14030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row pc-grey\"\u003e\n\u003cth class=\"pc-feature-cell\" colspan=\"2\" scope=\"row\"\u003eOxidation Resistance\u003c\/th\u003e\n\u003ctd\u003eExcellent - 100%\u003c\/td\u003e\n\u003ctd\u003eEN ISO 13438\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row\"\u003e\n\u003cth class=\"pc-feature-cell\" colspan=\"2\" scope=\"row\"\u003eCompressive Strength\u003c\/th\u003e\n\u003ctd\u003e250kN\u003c\/td\u003e\n\u003ctd\u003eBS EN ISO 25619-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row pc-grey\"\u003e\n\u003cth class=\"pc-feature-cell\" colspan=\"2\" scope=\"row\"\u003eDeclared Application\u003c\/th\u003e\n\u003ctd\u003eType V damp-proof sheet\u003c\/td\u003e\n\u003ctd\u003eBS EN 13967:2012+A1:2017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row\"\u003e\n\u003cth class=\"pc-feature-cell\" colspan=\"2\" scope=\"row\"\u003eDirect Plaster Or Render Fixing Quantity\u003c\/th\u003e\n\u003ctd\u003e16plugs\/m²\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row pc-grey\"\u003e\n\u003cth class=\"pc-feature-cell\" colspan=\"2\" scope=\"row\"\u003eDot-And-Dab Plasterboard Fixing Quantity\u003c\/th\u003e\n\u003ctd\u003e10plugs\/m²\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row\"\u003e\n\u003cth class=\"pc-feature-cell\" colspan=\"2\" scope=\"row\"\u003eGuarantee Against Membrane Deterioration\u003c\/th\u003e\n\u003ctd\u003e30 years\u003c\/td\u003e\n\u003ctd\u003eManufacturer statement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row pc-grey\"\u003e\n\u003cth class=\"pc-feature-cell\" colspan=\"2\" scope=\"row\"\u003ePublished Life Expectancy\u003c\/th\u003e\n\u003ctd\u003eAt least 50 years, subject to correct installation, protection and service conditions\u003c\/td\u003e\n\u003ctd\u003eManufacturer statement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"pc-column-head\" scope=\"col\"\u003eNewton Product Code\u003c\/th\u003e\n\u003cth class=\"pc-column-head\" scope=\"col\"\u003eKit Membrane Roll Size\u003c\/th\u003e\n\u003cth class=\"pc-column-head\" scope=\"col\"\u003eNominal Membrane Coverage\u003c\/th\u003e\n\u003cth class=\"pc-column-head\" scope=\"col\"\u003ePackaged Membrane Roll Weight\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row\"\u003e\n\u003cth class=\"pc-feature-cell\" scope=\"row\"\u003eM16\u003c\/th\u003e\n\u003ctd\u003e1m x 10m\u003c\/td\u003e\n\u003ctd\u003e10m²\u003c\/td\u003e\n\u003ctd\u003e6.2kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row pc-grey\"\u003e\n\u003cth class=\"pc-feature-cell\" scope=\"row\"\u003eM21\u003c\/th\u003e\n\u003ctd\u003e1m x 20m\u003c\/td\u003e\n\u003ctd\u003e20m²\u003c\/td\u003e\n\u003ctd\u003e11.34kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row\"\u003e\n\u003cth class=\"pc-feature-cell\" scope=\"row\"\u003eM9\u003c\/th\u003e\n\u003ctd\u003e1.2m x 10m\u003c\/td\u003e\n\u003ctd\u003e12m²\u003c\/td\u003e\n\u003ctd\u003e7.5kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row pc-grey\"\u003e\n\u003cth class=\"pc-feature-cell\" scope=\"row\"\u003eM22\u003c\/th\u003e\n\u003ctd\u003e2m x 20m\u003c\/td\u003e\n\u003ctd\u003e40m²\u003c\/td\u003e\n\u003ctd\u003e24.6kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"pc-table-note\" colspan=\"4\"\u003eNominal coverage is the full uncut roll area. Allow for trimming, openings, corners, return walls, reveals and site waste when calculating the quantity required.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"pc-section-title\" colspan=\"4\" scope=\"colgroup\"\u003eEssential Characteristics\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"pc-column-head\" scope=\"col\"\u003eEssential Characteristic\u003c\/th\u003e\n\u003cth class=\"pc-column-head\" scope=\"col\"\u003ePerformance\u003c\/th\u003e\n\u003cth class=\"pc-column-head\" scope=\"col\"\u003eTest Standard\u003c\/th\u003e\n\u003cth class=\"pc-column-head\" scope=\"col\"\u003eHarmonised Technical Specification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row\"\u003e\n\u003cth class=\"pc-feature-cell\" scope=\"row\"\u003eWatertightness, 60kPa For 24 Hours\u003c\/th\u003e\n\u003ctd\u003ePass\u003c\/td\u003e\n\u003ctd\u003eEN 1928\u003c\/td\u003e\n\u003ctd\u003eBS EN 13967:2012+A1:2017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row pc-grey\"\u003e\n\u003cth class=\"pc-feature-cell\" scope=\"row\"\u003eCompressive Strength\u003c\/th\u003e\n\u003ctd\u003e250kN\u003c\/td\u003e\n\u003ctd\u003eBS EN ISO 25619-2\u003c\/td\u003e\n\u003ctd\u003eBS EN 13967:2012+A1:2017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row\"\u003e\n\u003cth class=\"pc-feature-cell\" scope=\"row\"\u003eResistance To Tearing\u003c\/th\u003e\n\u003ctd\u003eMD: NPD; CMD: NPD\u003c\/td\u003e\n\u003ctd\u003eEN 12310-1\u003c\/td\u003e\n\u003ctd\u003eBS EN 13967:2012+A1:2017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row pc-grey\"\u003e\n\u003cth class=\"pc-feature-cell\" scope=\"row\"\u003eElongation (%)\u003c\/th\u003e\n\u003ctd\u003eMD: NPD; CMD: NPD\u003c\/td\u003e\n\u003ctd\u003eEN 12311-2\u003c\/td\u003e\n\u003ctd\u003eBS EN 13967:2012+A1:2017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row\"\u003e\n\u003cth class=\"pc-feature-cell\" scope=\"row\"\u003eCompressive Creep \/ Resistance To Static Load\u003c\/th\u003e\n\u003ctd\u003eNPD\u003c\/td\u003e\n\u003ctd\u003eEN 13967 Annex B\u003c\/td\u003e\n\u003ctd\u003eBS EN 13967:2012+A1:2017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row pc-grey\"\u003e\n\u003cth class=\"pc-feature-cell\" scope=\"row\"\u003eImpact Resistance\u003c\/th\u003e\n\u003ctd\u003eNPD\u003c\/td\u003e\n\u003ctd\u003eEN 12691 Method A\u003c\/td\u003e\n\u003ctd\u003eBS EN 13967:2012+A1:2017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row\"\u003e\n\u003cth class=\"pc-feature-cell\" scope=\"row\"\u003eDurability Against Ageing\u003c\/th\u003e\n\u003ctd\u003eNPD\u003c\/td\u003e\n\u003ctd\u003eEN 1296 \/ EN 1928\u003c\/td\u003e\n\u003ctd\u003eBS EN 13967:2012+A1:2017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row pc-grey\"\u003e\n\u003cth class=\"pc-feature-cell\" scope=\"row\"\u003eDurability Against Chemicals\u003c\/th\u003e\n\u003ctd\u003eNPD\u003c\/td\u003e\n\u003ctd\u003eEN 1847 \/ EN 1928\u003c\/td\u003e\n\u003ctd\u003eBS EN 13967:2012+A1:2017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row\"\u003e\n\u003cth class=\"pc-feature-cell\" scope=\"row\"\u003eReaction To Fire\u003c\/th\u003e\n\u003ctd\u003eEuroclass E\u003c\/td\u003e\n\u003ctd\u003eEN 13501-1\u003c\/td\u003e\n\u003ctd\u003eBS EN 13967:2012+A1:2017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row pc-grey\"\u003e\n\u003cth class=\"pc-feature-cell\" scope=\"row\"\u003eJoint Tensile Shear Resistance\u003c\/th\u003e\n\u003ctd\u003eNot stated\u003c\/td\u003e\n\u003ctd\u003eEN 12317-2\u003c\/td\u003e\n\u003ctd\u003eBS EN 13967:2012+A1:2017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"pc-table-note\" colspan=\"4\"\u003eNPD means No Performance Determined. MD means machine direction; CMD means cross-machine direction.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch5\u003eInstallation\u003c\/h5\u003e\n\u003cstyle\u003e\n  .pc-newton-newtonite-lath-ancillary-table-swipe {\n    display: none;\n    margin: 0 0 6px;\n    color: #555;\n    font: 600 13px\/1.3 inherit;\n  }\n\n  .pc-newton-newtonite-lath-ancillary-table-wrap {\n    width: 100%;\n    max-width: 100%;\n    margin: 24px 0;\n    position: relative;\n    overflow-x: visible;\n  }\n\n  .pc-newton-newtonite-lath-ancillary-table {\n    width: 100%;\n    max-width: 100%;\n    min-width: 0;\n    table-layout: fixed;\n    border-collapse: collapse;\n    font-family: inherit;\n    font-size: 16px;\n    line-height: 1.35;\n    color: #111;\n    background: #fff;\n  }\n\n  .pc-newton-newtonite-lath-ancillary-table th,\n  .pc-newton-newtonite-lath-ancillary-table td {\n    border: 5px solid #fff;\n    padding: 9px 12px;\n    vertical-align: top;\n    text-align: left;\n    font-weight: 400;\n    overflow-wrap: anywhere;\n  }\n\n  .pc-newton-newtonite-lath-ancillary-table .pc-main-title {\n    padding: 14px 18px;\n    background: #7f7f7f;\n    color: #fff;\n    text-align: center;\n    text-transform: uppercase;\n    font-size: 30px;\n    line-height: 1.15;\n    font-weight: 700;\n  }\n\n  .pc-newton-newtonite-lath-ancillary-table .pc-section-title {\n    padding: 11px 12px;\n    background: #8f8f8f;\n    color: #fff;\n    text-align: left;\n    font-size: 22px;\n    line-height: 1.2;\n    font-weight: 700;\n  }\n\n  .pc-newton-newtonite-lath-ancillary-table .pc-column-head {\n    background: #a6a6a6;\n    color: #111;\n    text-align: left;\n    font-size: 18px;\n    line-height: 1.25;\n    font-weight: 700;\n  }\n\n  .pc-newton-newtonite-lath-ancillary-table .pc-data-row {\n    background: #fff;\n  }\n\n  .pc-newton-newtonite-lath-ancillary-table .pc-data-row.pc-grey {\n    background: #d9d9d9;\n  }\n\n  .pc-newton-newtonite-lath-ancillary-table .pc-product-cell {\n    color: #111;\n    text-align: left;\n    font-weight: 700;\n  }\n\n  .pc-newton-newtonite-lath-ancillary-table .pc-product-status {\n    display: block;\n    margin-top: 4px;\n    font-weight: 400;\n  }\n\n  @media screen and (max-width: 767px), (hover: none) and (pointer: coarse) {\n    .pc-newton-newtonite-lath-ancillary-table-swipe {\n      display: block;\n    }\n\n    .pc-newton-newtonite-lath-ancillary-table-wrap {\n      overflow-x: auto;\n      -webkit-overflow-scrolling: touch;\n    }\n\n    .pc-newton-newtonite-lath-ancillary-table {\n      min-width: 820px;\n      font-size: 14px;\n    }\n\n    .pc-newton-newtonite-lath-ancillary-table th,\n    .pc-newton-newtonite-lath-ancillary-table td {\n      border-width: 4px;\n      padding: 7px 9px;\n    }\n\n    .pc-newton-newtonite-lath-ancillary-table .pc-main-title {\n      padding: 11px 13px;\n      font-size: 23px;\n    }\n\n    .pc-newton-newtonite-lath-ancillary-table .pc-section-title {\n      padding: 9px;\n      font-size: 18px;\n    }\n\n    .pc-newton-newtonite-lath-ancillary-table .pc-column-head {\n      font-size: 16px;\n    }\n  }\n\u003c\/style\u003e\n\u003cp class=\"pc-newton-newtonite-lath-ancillary-table-swipe\" aria-hidden=\"true\"\u003eSwipe horizontally to view the full table →\u003c\/p\u003e\n\u003cdiv class=\"pc-newton-newtonite-lath-ancillary-table-wrap\" role=\"region\" aria-label=\"Newton Newtonite Lath membrane kit components and ancillary products table\"\u003e\n\u003ctable class=\"pc-newton-newtonite-lath-ancillary-table\" aria-label=\"Newton Newtonite Lath Kit Components And Ancillary Products\"\u003e\n\u003ccolgroup\u003e \u003ccol style=\"width: 24%;\"\u003e \u003ccol style=\"width: 76%;\"\u003e \u003c\/colgroup\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"pc-main-title\" colspan=\"2\" scope=\"colgroup\"\u003eNewton Newtonite Lath Kit Components And Ancillary Products\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth class=\"pc-section-title\" colspan=\"2\" scope=\"colgroup\"\u003eFixing Products\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"pc-column-head\" scope=\"col\"\u003eProduct\u003c\/th\u003e\n\u003cth class=\"pc-column-head\" scope=\"col\"\u003ePurpose\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row\"\u003e\n\u003cth class=\"pc-product-cell\" scope=\"row\"\u003e\n\u003ca href=\"https:\/\/www.platinumchemicals.co.uk\/products\/newton-newtonite-mesh-plugs-damp-proof-membrane-fixing\" rel=\"noopener\" target=\"_blank\"\u003eNewton Newtonite Mesh Plugs\u003c\/a\u003e \u003cspan class=\"pc-product-status\"\u003e(Included)\u003c\/span\u003e\n\u003c\/th\u003e\n\u003ctd\u003eRecommended 60mm fixings for suitable internal masonry. The 10m², 12m², 20m² and 40m² kits contain 160, 200, 320 and 650 plugs respectively. Seal fixing penetrations with Newtonite 801 Mastic.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row pc-grey\"\u003e\n\u003cth class=\"pc-product-cell\" scope=\"row\"\u003e\n\u003ca href=\"https:\/\/www.platinumchemicals.co.uk\/products\/newton-newtonite-cob-plugs-expanding-membrane-fixings\" rel=\"noopener\" target=\"_blank\"\u003eNewton Newtonite Cob Plugs\u003c\/a\u003e \u003cspan class=\"pc-product-status\"\u003e(Additional product)\u003c\/span\u003e\n\u003c\/th\u003e\n\u003ctd\u003eLonger expanding membrane fixings for suitable slightly friable mortar and compatible weak backgrounds. Select the correct drilling depth and seal the fixing penetrations as specified.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row\"\u003e\n\u003cth class=\"pc-product-cell\" scope=\"row\"\u003e\n\u003ca href=\"https:\/\/www.platinumchemicals.co.uk\/products\/sds-drill-bit-8mm\" rel=\"noopener\" target=\"_blank\"\u003eEvolution 8mm x 160mm SDS Plus Masonry Drill Bit\u003c\/a\u003e \u003cspan class=\"pc-product-status\"\u003e(Included)\u003c\/span\u003e\n\u003c\/th\u003e\n\u003ctd\u003eFor drilling holes for the recommended Newtonite Mesh Plugs. The 10m² and 12m² kits contain one bit; the 20m² and 40m² kits contain two bits.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row pc-grey\"\u003e\n\u003cth class=\"pc-product-cell\" scope=\"row\"\u003e\n\u003ca href=\"https:\/\/www.platinumchemicals.co.uk\/products\/evolution-sds-drill-bit-10mm\" rel=\"noopener\" target=\"_blank\"\u003eEvolution 10mm SDS Plus Masonry Drill Bit\u003c\/a\u003e \u003cspan class=\"pc-product-status\"\u003e(Additional product)\u003c\/span\u003e\n\u003c\/th\u003e\n\u003ctd\u003eSuitable diameter for Newtonite Cob Plug holes where those expanding fixings are specified. Select the usable length to suit the plug and required substrate embedment.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row\"\u003e\n\u003cth class=\"pc-product-cell\" scope=\"row\"\u003eGalvanised Clout Nails \u003cspan class=\"pc-product-status\"\u003e(Additional product)\u003c\/span\u003e\n\u003c\/th\u003e\n\u003ctd\u003eFixings specified for attaching Newtonite Lath to suitable timber or plywood. Coordinate nail selection and sealed fixing details with the condition of the supporting background.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"pc-section-title\" colspan=\"2\" scope=\"colgroup\"\u003eJointing, Sealing And Detailing Products\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"pc-column-head\" scope=\"col\"\u003eProduct\u003c\/th\u003e\n\u003cth class=\"pc-column-head\" scope=\"col\"\u003ePurpose\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row\"\u003e\n\u003cth class=\"pc-product-cell\" scope=\"row\"\u003e\n\u003ca href=\"https:\/\/www.platinumchemicals.co.uk\/products\/newton-mesh-tape-plaster-membrane-jointing-tape-a25\" rel=\"noopener\" target=\"_blank\"\u003eNewton Mesh Tape\u003c\/a\u003e \u003cspan class=\"pc-product-status\"\u003e(Additional product)\u003c\/span\u003e\n\u003c\/th\u003e\n\u003ctd\u003eSingle-sided sealing tape for face-sealing close butt joints and compatible repairs. Its textured upper surface maintains the key for plaster or render. Supplied in 100mm x 10m rolls.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row pc-grey\"\u003e\n\u003cth class=\"pc-product-cell\" scope=\"row\"\u003e\n\u003ca href=\"https:\/\/www.platinumchemicals.co.uk\/products\/newton-newtonite-801-mastic-damp-proof-membrane-sealant\" rel=\"noopener\" target=\"_blank\"\u003eNewton Newtonite 801 Mastic Sealant\u003c\/a\u003e \u003cspan class=\"pc-product-status\"\u003e(Included)\u003c\/span\u003e\n\u003c\/th\u003e\n\u003ctd\u003eSeals fixing holes and compatible penetrations against damp bridging. The 10m² and 12m² kits contain two cartridges; the 20m² kit three cartridges and the 40m² kit four cartridges.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"pc-section-title\" colspan=\"2\" scope=\"colgroup\"\u003ePlastering And Finishing Products\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"pc-column-head\" scope=\"col\"\u003eProduct\u003c\/th\u003e\n\u003cth class=\"pc-column-head\" scope=\"col\"\u003ePurpose\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row\"\u003e\n\u003cth class=\"pc-product-cell\" scope=\"row\"\u003eNewtonite Finishing Profile \u003cspan class=\"pc-product-status\"\u003e(Additional product)\u003c\/span\u003e\n\u003c\/th\u003e\n\u003ctd\u003eA 2m plaster-stop profile fitted with the membrane to maintain 20-25mm clearance beneath plaster or render. Not recommended on uneven wall runs or where the membrane continues below the slab.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row pc-grey\"\u003e\n\u003cth class=\"pc-product-cell\" scope=\"row\"\u003eTarmac Whitewall One Coat Plaster \u003cspan class=\"pc-product-status\"\u003e(Additional product)\u003c\/span\u003e\n\u003c\/th\u003e\n\u003ctd\u003eNewton’s recommended plaster for this membrane, applied in two separate 6mm coats with at least 24 hours between coats. An optional 2mm finishing coat may be added.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row\"\u003e\n\u003cth class=\"pc-product-cell\" scope=\"row\"\u003eSpecified Cement\/Lime Render Materials \u003cspan class=\"pc-product-status\"\u003e(Additional product)\u003c\/span\u003e\n\u003c\/th\u003e\n\u003ctd\u003eClean, well-graded sharp sand, cement and lime for the specified two-coat internal render. Maintain the correct mix ratios, 7mm coat thicknesses and curing intervals.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row pc-grey\"\u003e\n\u003cth class=\"pc-product-cell\" scope=\"row\"\u003eNHL3.5 And Suitable Sand \u003cspan class=\"pc-product-status\"\u003e(Additional product)\u003c\/span\u003e\n\u003c\/th\u003e\n\u003ctd\u003eMaterials for the specified natural hydraulic lime finish, mixed at 2.5 parts sand to 1 part NHL3.5 and applied in two 10mm coats.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row\"\u003e\n\u003cth class=\"pc-product-cell\" scope=\"row\"\u003eCompatible Plasterboard And Proprietary Adhesive \u003cspan class=\"pc-product-status\"\u003e(Additional product)\u003c\/span\u003e\n\u003c\/th\u003e\n\u003ctd\u003eBoards and adhesive selected for the meshed membrane and room conditions. Distribute adhesive to the required 50% coverage and provide additional mechanical restraint for laminated boards where required.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"pc-section-title\" colspan=\"2\" scope=\"colgroup\"\u003eDamp Treatment And Supporting Products\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"pc-column-head\" scope=\"col\"\u003eProduct\u003c\/th\u003e\n\u003cth class=\"pc-column-head\" scope=\"col\"\u003ePurpose\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row\"\u003e\n\u003cth class=\"pc-product-cell\" scope=\"row\"\u003e\n\u003ca href=\"https:\/\/www.platinumchemicals.co.uk\/products\/dampsolve-damp-proof-dpc-cream\" rel=\"noopener\" target=\"_blank\"\u003eDampSolve Damp Proof DPC Cream\u003c\/a\u003e \u003cspan class=\"pc-product-status\"\u003e(Additional product)\u003c\/span\u003e\n\u003c\/th\u003e\n\u003ctd\u003ePlatinum-branded remedial DPC cream for suitable masonry where rising damp has been diagnosed and a separate injection treatment forms part of the selected remedial specification.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row pc-grey\"\u003e\n\u003cth class=\"pc-product-cell\" scope=\"row\"\u003e\n\u003ca href=\"https:\/\/www.platinumchemicals.co.uk\/products\/dry-rot-masonry-treatment-lignum-pro-m50\" rel=\"noopener\" target=\"_blank\"\u003eLignum Pro M50 Masonry Biocide\u003c\/a\u003e \u003cspan class=\"pc-product-status\"\u003e(Additional product)\u003c\/span\u003e\n\u003c\/th\u003e\n\u003ctd\u003eConcentrated masonry biocide for correctly diagnosed dry-rot contamination in suitable masonry, used as part of the complete remedial specification. Other biological problems require their own specialist assessment and treatment.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row\"\u003e\n\u003cth class=\"pc-product-cell\" scope=\"row\"\u003eCompatible Background Repair Materials \u003cspan class=\"pc-product-status\"\u003e(Additional product)\u003c\/span\u003e\n\u003c\/th\u003e\n\u003ctd\u003eSuitable materials for repairing defective render and levelling significant background irregularities before membrane installation, helping maintain an even thickness in the subsequent plaster or render finish.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eHealth \u0026amp; Safety And Installer Competency\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eRead the membrane installation instructions and the separate safety information for tapes, mastics, treatments, adhesives and finishing materials before work begins. Wear suitable gloves and eye protection, and use appropriate dust control and hearing protection when preparing masonry or drilling fixing holes.\u003c\/p\u003e\n\u003cp\u003eCheck for concealed services before drilling. Support membrane sections during cutting and use a suitable knife, scissors or shears. Handle rolls with appropriate assistance where their size, weight or working position makes this necessary.\u003c\/p\u003e\n\u003cp\u003eThe cause of dampness and the suitability of the wall should be assessed before installation. Active decay, structurally defective backgrounds, severe contamination or uncertain moisture sources require assessment by an appropriately experienced remedial specialist.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eIntended Use And System Selection\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eNewtonite Lath is a damp-proofing membrane for internal faces of above-ground, non-earth-retaining walls. It provides separation between the background and a suitable new plaster, render, hydraulic lime or dot-and-dab plasterboard finish.\u003c\/p\u003e\n\u003cp\u003eDo not use it on walls with earth against the opposite side or where groundwater ingress or hydrostatic pressure is present. It is not a substitute for a waterproofing system designed for those conditions.\u003c\/p\u003e\n\u003cp\u003eChoose the finishing system before fixing the membrane. The finish determines the fixing quantity, overall wall build-up, curing programme and details at floors, openings, sockets and skirtings. Where a mesh key is unnecessary because an independent frame or masonry lining is intended, Newton Newtonite Non-Meshed Damp Proof Membrane is the appropriate alternative to consider.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003eSuitable Substrates And Finishes\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003cstyle\u003e\n  .pc-newton-newtonite-lath-substrates-table-swipe {\n    display: none;\n    margin: 0 0 6px;\n    color: #555;\n    font: 600 13px\/1.3 inherit;\n  }\n\n  .pc-newton-newtonite-lath-substrates-table-wrap {\n    width: 100%;\n    max-width: 100%;\n    margin: 24px 0;\n    position: relative;\n    overflow-x: visible;\n  }\n\n  .pc-newton-newtonite-lath-substrates-table {\n    width: 100%;\n    max-width: 100%;\n    min-width: 0;\n    table-layout: fixed;\n    border-collapse: collapse;\n    font-family: inherit;\n    font-size: 16px;\n    line-height: 1.35;\n    color: #111;\n    background: #fff;\n  }\n\n  .pc-newton-newtonite-lath-substrates-table th,\n  .pc-newton-newtonite-lath-substrates-table td {\n    border: 5px solid #fff;\n    padding: 9px 12px;\n    vertical-align: top;\n    text-align: left;\n    font-weight: 400;\n    overflow-wrap: anywhere;\n  }\n\n  .pc-newton-newtonite-lath-substrates-table .pc-main-title {\n    padding: 14px 18px;\n    background: #7f7f7f;\n    color: #fff;\n    text-align: center;\n    text-transform: uppercase;\n    font-size: 30px;\n    line-height: 1.15;\n    font-weight: 700;\n  }\n\n  .pc-newton-newtonite-lath-substrates-table .pc-column-head {\n    background: #a6a6a6;\n    color: #111;\n    text-align: left;\n    font-size: 18px;\n    line-height: 1.25;\n    font-weight: 700;\n  }\n\n  .pc-newton-newtonite-lath-substrates-table .pc-data-row {\n    background: #fff;\n  }\n\n  .pc-newton-newtonite-lath-substrates-table .pc-data-row.pc-grey {\n    background: #d9d9d9;\n  }\n\n  .pc-newton-newtonite-lath-substrates-table .pc-application-cell {\n    color: #111;\n    text-align: left;\n    font-weight: 700;\n  }\n\n  @media screen and (max-width: 767px), (hover: none) and (pointer: coarse) {\n    .pc-newton-newtonite-lath-substrates-table-swipe {\n      display: block;\n    }\n\n    .pc-newton-newtonite-lath-substrates-table-wrap {\n      overflow-x: auto;\n      -webkit-overflow-scrolling: touch;\n    }\n\n    .pc-newton-newtonite-lath-substrates-table {\n      min-width: 900px;\n      font-size: 14px;\n    }\n\n    .pc-newton-newtonite-lath-substrates-table th,\n    .pc-newton-newtonite-lath-substrates-table td {\n      border-width: 4px;\n      padding: 7px 9px;\n    }\n\n    .pc-newton-newtonite-lath-substrates-table .pc-main-title {\n      padding: 11px 13px;\n      font-size: 23px;\n    }\n\n    .pc-newton-newtonite-lath-substrates-table .pc-column-head {\n      font-size: 16px;\n    }\n  }\n\u003c\/style\u003e\n\u003cp class=\"pc-newton-newtonite-lath-substrates-table-swipe\" aria-hidden=\"true\"\u003eSwipe horizontally to view the full table →\u003c\/p\u003e\n\u003cdiv class=\"pc-newton-newtonite-lath-substrates-table-wrap\" role=\"region\" aria-label=\"Newton Newtonite Lath membrane kit suitable substrates and finishes table\"\u003e\n\u003ctable class=\"pc-newton-newtonite-lath-substrates-table\" aria-label=\"Newton Newtonite Lath Membrane Kit Suitable Substrates And Finishes\"\u003e\n\u003ccolgroup\u003e \u003ccol style=\"width: 18%;\"\u003e \u003ccol style=\"width: 25%;\"\u003e \u003ccol style=\"width: 26%;\"\u003e \u003ccol style=\"width: 31%;\"\u003e \u003c\/colgroup\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"pc-main-title\" colspan=\"4\" scope=\"colgroup\"\u003eNewton Newtonite Lath Membrane Kit Suitable Substrates And Finishes\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"pc-column-head\" scope=\"col\"\u003eApplication\u003c\/th\u003e\n\u003cth class=\"pc-column-head\" scope=\"col\"\u003eSuitable Background\u003c\/th\u003e\n\u003cth class=\"pc-column-head\" scope=\"col\"\u003eCompatible Finish\u003c\/th\u003e\n\u003cth class=\"pc-column-head\" scope=\"col\"\u003eImportant Requirements\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr class=\"pc-data-row\"\u003e\n\u003cth class=\"pc-application-cell\" scope=\"row\"\u003eAbove-Ground Masonry Walls\u003c\/th\u003e\n\u003ctd\u003eSound brickwork, blockwork, concrete or suitable stone masonry\u003c\/td\u003e\n\u003ctd\u003eSpecified plaster, cement\/lime render, hydraulic lime or dot-and-dab plasterboard\u003c\/td\u003e\n\u003ctd\u003eUse the correct membrane plugs and seal fixing holes. The wall must not retain earth.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row pc-grey\"\u003e\n\u003cth class=\"pc-application-cell\" scope=\"row\"\u003eExisting Rendered Walls\u003c\/th\u003e\n\u003ctd\u003eFirmly bonded, stable render over a suitable supporting wall\u003c\/td\u003e\n\u003ctd\u003eThe selected compatible plaster, render or plasterboard system\u003c\/td\u003e\n\u003ctd\u003eRemove loose or defective areas and ensure fixings obtain dependable anchorage in the supporting substrate.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row\"\u003e\n\u003cth class=\"pc-application-cell\" scope=\"row\"\u003eSlightly Friable Mortar Backgrounds\u003c\/th\u003e\n\u003ctd\u003eSuitable weak mortar backgrounds capable of supporting the complete finish\u003c\/td\u003e\n\u003ctd\u003eA compatible finish within the assessed substrate and fixing capacity\u003c\/td\u003e\n\u003ctd\u003eUse Newtonite Cob Plugs where appropriate. Repair structurally unsound or severely crumbling material before installation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"pc-data-row pc-grey\"\u003e\n\u003cth class=\"pc-application-cell\" scope=\"row\"\u003eTimber Or Plywood Backgrounds\u003c\/th\u003e\n\u003ctd\u003eSound, suitable timber or plywood with adequate support\u003c\/td\u003e\n\u003ctd\u003eFinish selected for the complete background and membrane construction\u003c\/td\u003e\n\u003ctd\u003eUse galvanised clout nails as specified and maintain sealed penetrations and joints.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eSurface Preparation\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eRemove debris, organic matter and unstable material. Existing plaster should be removed because dampness can soften it and weaken the membrane fixing. Firmly bonded render may remain; remove loose, crumbling or detached render and repair damaged areas before fixing.\u003c\/p\u003e\n\u003cp\u003eObtain a reasonably flat background. Where substantial undulations exist, level the supporting wall with a suitable sand\/cement repair or dubbing-out specification before installing Newtonite Lath. Avoid compensating for an uneven background with excessively variable plaster or render thickness over the membrane.\u003c\/p\u003e\n\u003cp\u003eDiagnose and address the source of dampness where practicable. Repair leaks and relevant external defects. Use DampSolve Damp Proof DPC Cream only where a separately specified injection treatment is appropriate to diagnosed rising damp.\u003c\/p\u003e\n\u003cp\u003eHave wet rot or dry rot assessed and treated by a qualified remedial specialist. Lignum Pro M50 may be used on suitable masonry affected by diagnosed dry rot in accordance with its label and the complete treatment specification. It is not a general-purpose treatment for every form of biological contamination. Use an appropriate treatment for other identified growth before enclosing the wall.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eTools And Ancillary Products Required\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eTypical tools include a tape measure, pencil, long spirit level or rotating laser, sharp utility knife, scissors or shears, suitable SDS drill and masonry bits, wide-headed hammer or mallet, and clean cloths for preparing taped joints. Select drilling equipment for the actual plug and substrate.\u003c\/p\u003e\n\u003cp\u003eThe kits include Newtonite Mesh Plugs, Newtonite 801 Mastic and 8mm x 160mm SDS Plus drill bits. Newton Mesh Tape is supplied separately for butt joints and suitable repairs. Newtonite Cob Plugs are used where the suitable weak-background fixing is required. Choose the plaster, render, adhesive, boards and any finishing profiles before setting out the membrane.\u003c\/p\u003e\n\u003cp\u003eIn cold or damp conditions, controlled warm air may assist preparation of the meshed face for taping. Use a heat gun cautiously to remove surface moisture without overheating the sheet, mesh or surrounding materials.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eCutting And Setting Out\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eMeasure the wall and select horizontal or vertical sheet orientation to suit wall dimensions and handling access. Plan joints, openings, corners, return walls, reveals and service penetrations before cutting. Include the areas needed beyond the main wall face when calculating roll quantities.\u003c\/p\u003e\n\u003cp\u003eCut with a sharp utility knife, scissors or shears, supporting the sheet to produce clean edges. Keep the mesh intact over areas that will receive a bonded finish and avoid unnecessary cuts or punctures.\u003c\/p\u003e\n\u003cp\u003eWhere practicable, continue the membrane into the ceiling void and down past the slab to the oversite. Otherwise, finish it tightly to the soffit and floor finish. Do not leave deliberate ventilation gaps behind the membrane. The separate 20-25mm clearance beneath plaster or render prevents floor bridging and must not be confused with an open membrane-cavity detail.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eWall Installation And Mesh Plug Fixing\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003ePlace the studs against the wall and the meshed surface towards the room. Align the first sheet accurately and hold it taut and square while installing the initial fixings. Avoid sagging, bulging or excessive tension, as movement behind the finish can contribute to cracking.\u003c\/p\u003e\n\u003cp\u003eUse the recommended 60mm Newtonite Mesh Plugs on suitable masonry. The current plug uses a 8mm drilled hole; select the drilling arrangement to suit the actual substrate and plug instructions. When using the recommended 60mm Newtonite Mesh Plugs, drill through the membrane into the wall to a depth of at least 60mm, allowing additional clearance for drilling debris so the plug seats fully. For other plug types or lengths, follow the drilling depth specified for the selected fixing.\u003c\/p\u003e\n\u003cp\u003eApply Newtonite 801 Mastic around the fixing hole before driving the plug home with a wide-headed hammer or mallet. The mastic must seal the penetration between the plug and membrane. Add the remaining fixings in the pattern required for the selected finish, ensuring the sheet remains stable and properly supported.\u003c\/p\u003e\n\u003cp\u003eDo not install membrane fixings below -5°C or above +30°C. Follow the separate application limits for mastic, tape, background repairs and finishing products.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2617\/5036\/files\/Newtonite_Lath_2_1024x1024.png?v=1793882669\" alt=\"\" style=\"float: none;\"\u003e\u003c\/div\u003e\n\u003ch6 style=\"text-align: center;\"\u003e\n\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eNewtonite Mesh Plugs hold the membrane taut and securely in place, providing stable support for the chosen wall finish.\u003c\/strong\u003e\u003c\/em\u003e\u003cbr\u003e\n\u003c\/h6\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eInstallation Drawings\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch6\u003ePlaster Finish Linked To DPM Below Slab\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/h6\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2617\/5036\/files\/Newtonite_Lath_4.png?v=1793885238\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2617\/5036\/files\/Newtonite_Lath_4_1024x1024.png?v=1793885238\" alt=\"\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch6\u003eDot \u0026amp; Dab Plasterboard Finish Linked To DPM Below Slab\u003cbr\u003e\n\u003c\/h6\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2617\/5036\/files\/Newtonite_Lath_5.png?v=1793885238\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2617\/5036\/files\/Newtonite_Lath_5_1024x1024.png?v=1793885238\" alt=\"\" style=\"float: none;\"\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch6\u003ePlaster Finish Into Timber Floor Void\u003cbr\u003e\n\u003c\/h6\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2617\/5036\/files\/Newtonite_Lath_6.png?v=1793885237\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2617\/5036\/files\/Newtonite_Lath_6_1024x1024.png?v=1793885237\" alt=\"\" style=\"float: none;\"\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch6\u003eDot \u0026amp; Dab Plasterboard Finish Into Timber Floor Void\u003cbr\u003e\n\u003c\/h6\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2617\/5036\/files\/Newtonite_Lath_7.png?v=1793885237\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2617\/5036\/files\/Newtonite_Lath_7_1024x1024.png?v=1793885237\" alt=\"\" style=\"float: none;\"\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch6\u003eLinked to Epoxy DPM Above Existing Concrete Slab\u003cbr\u003e\n\u003c\/h6\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2617\/5036\/files\/Newtonite_Lath_8.png?v=1793885654\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2617\/5036\/files\/Newtonite_Lath_8_1024x1024.png?v=1793885654\" alt=\"\" style=\"float: none;\"\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eFixing Quantities And Finish Support\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eFor direct plaster or render, use 16plugs\/m², with fixing centres no greater than 250mm. For dot-and-dab plasterboard, use 10plugs\/m², distributed to support the sheet and coordinate with the adhesive and board arrangement.\u003c\/p\u003e\n\u003cp\u003eUse closer or additional fixings where curved or uneven backgrounds, corners, edges, openings or local conditions require more support. Check that each fixing achieves dependable grip. The membrane must not move, sag or bulge beneath the chosen finish.\u003c\/p\u003e\n\u003cp\u003eCalculate plug quantities from the actual membrane area and detail layout. The stated fixing quantities do not replace an assessment of substrate condition or the support needed at small sections, returns and reveals.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eFixing To Friable Backgrounds, Timber And Plywood\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eNewtonite Cob Plugs may be used where suitable slightly friable mortar requires a longer expanding fixing. Use the correct 10mm drilling arrangement and depth for the selected plug, fit its expansion pin as instructed and maintain a sealed penetration with the appropriate mastic detail.\u003c\/p\u003e\n\u003cp\u003eA specialist plug cannot make structurally unsound masonry suitable. Repair severely crumbling or detached backgrounds and confirm they can support the membrane and finish before continuing.\u003c\/p\u003e\n\u003cp\u003eFor suitable timber or plywood backgrounds, Newton specifies galvanised clout nails. The supporting timber construction and fixing arrangement must suit the completed wall finish. Preserve the damp-proof separation at penetrations and do not treat the membrane as structural support for the lining.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eMembrane Jointing\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eBring adjoining sheet edges together as close butt joints, running horizontally or vertically as required by the layout. Do not overlap the studded sheets or leave open gaps between them.\u003c\/p\u003e\n\u003cp\u003eEnsure the meshed face is clean and dry, then centre Newton Mesh Tape over the joint so approximately equal widths bond to each sheet. Remove the release liner progressively and press firmly into the mesh across the full tape width. The textured tape surface maintains the key for the specified finish.\u003c\/p\u003e\n\u003cp\u003eIn cold or damp conditions, gently warm the joint area to evaporate surface moisture and help press the tape into the mesh. Avoid overheating or distorting the membrane. Replace contaminated or poorly bonded tape and inspect the full joint before applying the finish.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2617\/5036\/files\/Newtonite_Lath_9_1024x1024.png?v=1793884206\" alt=\"\" style=\"float: none;\"\u003e\u003c\/div\u003e\n\u003ch6 style=\"text-align: center;\"\u003e\n\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eNewton Mesh Tape seals butt joints between adjoining membrane sheets while maintaining a textured key for plaster or render.\u003c\/strong\u003e\u003c\/em\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/h6\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eCorners, Return Walls And Reveals\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eNewtonite Lath can be taken around corners where it forms neatly without becoming misshapen. Maintain the studs towards the background and the mesh towards the room throughout the turn.\u003c\/p\u003e\n\u003cp\u003eAt difficult corners, cut the membrane at a controlled position, form a close butt joint and seal it with Newton Mesh Tape. Support the sheet edges adequately and avoid loose folds that would create uneven finishing thicknesses.\u003c\/p\u003e\n\u003cp\u003eContinue the membrane 300mm onto return walls to isolate adjoining finishes from dampness transmitted from the main treated wall. The sheet can also continue into reveals. Coordinate the membrane, mesh tape, window or door frame and finish so dampness cannot bypass the treated area at its perimeter.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003ePipes, Services And Later Wall Fixings\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003ePlan services before fitting the membrane and minimise penetrations through the damp-proof layer. Cut closely around pipes and other protrusions, then apply Newtonite 801 Mastic continuously around the opening to prevent moisture or salts bridging into the finish.\u003c\/p\u003e\n\u003cp\u003eWhere brackets or other fittings require fixing bolts through the membrane, introduce the mastic before inserting the bolts. The anchor must provide adequate support in the background, while the sealed penetration preserves separation from the damp wall.\u003c\/p\u003e\n\u003cp\u003eThe membrane and finishing mesh do not carry heavy fixtures. Select suitable structural fixings for radiators, cupboards, shelving and similar loads, with the penetration detail planned and sealed before the finished wall is put into use.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eFinishing Profile And Floor Clearance\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eKeep plaster and render 20-25mm above floor level to prevent moisture bridging from the floor into the finish. Where suitable, fit Newtonite Finishing Profile at the same time as the membrane, before plastering or rendering begins.\u003c\/p\u003e\n\u003cp\u003eThe profile is supplied in 2m lengths and acts as a plaster stop. It is not recommended where the wall run is uneven or where the membrane continues down past the slab; those situations require a suitable alternative termination that retains the necessary finish clearance.\u003c\/p\u003e\n\u003cp\u003eOnce the finish is thoroughly dry, cover the clearance with timber skirting. Keep the membrane termination and the raised plaster\/render edge distinct: the membrane cavity is not intended to be deliberately ventilated.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eInternal Plaster Application\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eNewton recommends Tarmac Whitewall One Coat Plaster, applied to Newtonite Lath in two separate coats. Apply a 6mm scratch coat followed by a 6mm second or float coat, allowing at least 24 hours between plaster coats. If required, add a 3mm finishing coat.\u003c\/p\u003e\n\u003cp\u003eWork the plaster into the mesh and follow the plaster manufacturer's mixing, application and environmental requirements. Despite the product name, do not apply Whitewall as one single coat over this membrane.\u003c\/p\u003e\n\u003cp\u003eWhere a high-impact plaster finish is specified, Newton identifies Tarmac Backing Plaster and Tarmac High Impact Finishing Plaster. These high-impact materials are not suitable for high-humidity or wet areas such as swimming-pool surrounds. Allow plaster to dry thoroughly before decoration.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2617\/5036\/files\/Newtonite_Lath_3_1024x1024.png?v=1793882668\" alt=\"\" style=\"float: none;\"\u003e\u003c\/div\u003e\n\u003ch6 style=\"text-align: center;\"\u003e\n\u003cbr\u003e\u003cem\u003e\u003cstrong\u003ePlaster is worked firmly into Newtonite Lath’s mesh to create a strong mechanical key for the recommended two-coat internal plaster finish.\u003c\/strong\u003e\u003c\/em\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/h6\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eInternal Cement\/Lime Render Application\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eApply the traditional sand, cement and lime render in two 7mm coats, giving 14mm total render thickness. The scratch coat mix is 1 part lime, 1 part cement and 5 parts clean, well-graded sharp sand. The second or float coat mix is 1 part lime, 1 part cement and 6 parts sand.\u003c\/p\u003e\n\u003cp\u003eWork the scratch coat thoroughly into the mesh to stiffen the lath and create a suitable backing. Newton recommends mixing the lime and sand at least a day before use, adding cement when rendering. Allow each coat at least seven days, preferably ten days or longer where possible, with appropriate curing before applying another coat.\u003c\/p\u003e\n\u003cp\u003eKeep the render dampened as required and protect it from accelerated drying. Confirm the scratch coat has cured behind the mesh as well as at the surface before proceeding, without damaging the membrane. Dampen the scratch coat before the float coat. A smooth render finish is not recommended.\u003c\/p\u003e\n\u003cp\u003eWhere specified, form movement joints through the render to the membrane and fill with a suitable flexible polymer-based sealant without puncturing the sheet. Suitable angle and stop beads can be secured with dabs of the scratch-coat material. An optional 3mm finishing plaster coat may be applied after the render is fully cured.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2617\/5036\/files\/Newton_503_Mesh_Membrane_1_1024x1024.png?v=1793285444\" alt=\"\" style=\"float: none;\"\u003e\u003c\/div\u003e\n\u003ch6 style=\"text-align: center;\"\u003e\n\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eA 7mm cement\/lime scratch coat is worked into Newtonite Lath’s mesh and textured to provide a strong key for the second render coat.\u003c\/strong\u003e\u003c\/em\u003e\u003cbr\u003e\n\u003c\/h6\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eNatural Hydraulic Lime Application\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eUse NHL3.5 mixed with suitable sand at 2.5 parts sand to 1 part NHL3.5, following the material manufacturer's instructions. Apply a 10mm scratch coat and a 10mm second or float coat, giving 20mm combined thickness.\u003c\/p\u003e\n\u003cp\u003ePush the scratch coat firmly into the mesh and scratch the surface without breaking the mesh. Check it the following day and rub out any cracks. Leave it to set for at least seven days, protecting it from draughts and extremes of temperature.\u003c\/p\u003e\n\u003cp\u003eBefore the second coat, confirm that the material behind the mesh is set and reasonably hard, without puncturing the membrane. Dampen the scratch coat, apply and rule off the second coat, and protect and tend it as required. The second coat may provide the finished surface or receive a further compatible finishing coat.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eDot-And-Dab Plasterboard\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eUse suitable plasterboard and a proprietary adhesive compatible with the membrane and intended room conditions. Apply adhesive dabs to plug heads, board edges and the meshed membrane, providing 50% adhesive coverage over the membrane surface.\u003c\/p\u003e\n\u003cp\u003eCoordinate the board layout with the 10plugs\/m² membrane fixing arrangement, openings, corners and service positions. Set boards to the required line without crushing or displacing the membrane. Follow the board and adhesive manufacturer's requirements for setting, jointing and decoration.\u003c\/p\u003e\n\u003cp\u003eLaminated boards require additional mechanical restraint, with a fixing at each side in the upper half of the board. Position these fixings above the membrane height or, where they pass through the membrane, above the anticipated height of moisture in the wall, in accordance with Newton's detail. The complete board, adhesive, restraint and wall arrangement must satisfy the applicable fire requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eCuring, Drying And Decoration\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe membrane itself has no wet-curing period, but repairs, mastic, adhesive, plaster and render must reach the conditions required by their separate instructions. Do not begin finishing over unsealed penetrations, poorly bonded tape or unstable membrane sections.\u003c\/p\u003e\n\u003cp\u003eProtect cement\/lime render from rapid moisture loss caused by sunlight, draughts, heat or dehumidification. Maintain the specified curing conditions, dampening as required. Damp hessian with protective plastic sheeting may be used during warm conditions where appropriate to the render specification.\u003c\/p\u003e\n\u003cp\u003eDo not decorate plaster or render until thoroughly dry. Select decorations compatible with the chosen finish and maintain normal room ventilation and heating. Newtonite Lath isolates damp masonry but does not remove the need to control indoor humidity and condensation.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eNew Floor Slab And DPM Junctions\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eWhere a new slab is part of the above-ground refurbishment, Newton recommends fitting Newtonite Lath before the slab is laid. Arrange the floor damp-proof membrane to extend upwards in front of the wall membrane, ready for concrete placement.\u003c\/p\u003e\n\u003cp\u003eCoordinate the floor DPM, slab, insulation, finished floor level and raised plaster or render edge before installation. Preserve damp-proof continuity and protect the wall membrane during the pour and subsequent work.\u003c\/p\u003e\n\u003cp\u003eThis detail relates to an above-ground floor-to-wall damp-proofing junction. Newtonite Lath must remain within its non-earth-retaining application scope.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eInspection, Repairs And Protection\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eInspect the complete membrane before finishing. Check sheet orientation, secure fixing, mastic seals, close butt joints and fully bonded Mesh Tape. Examine corners, 300mm returns, reveals, service penetrations and floor junctions for any route that could bridge dampness into the finish.\u003c\/p\u003e\n\u003cp\u003eRepair damaged areas using compatible membrane and Newton Mesh Tape details, maintaining a continuous seal and keyed finishing surface. Replace sections where a reliable repair cannot be formed. Do not conceal loose plugs, torn mesh, unsealed holes or tape that has failed to bond.\u003c\/p\u003e\n\u003cp\u003eProtect the installation from accidental damage and tell follow-on trades where the membrane is located. Subsequent drilling must use a planned, sealed fixing detail. The completed finish must protect the membrane from exposure, physical damage and wear.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eKey Limitations\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eKit Coverage And Contents:\u003c\/strong\u003e Kit sizes refer to nominal membrane area. Allow for cutting and waste, and select separately supplied Mesh Tape and finishing materials for the measured installation.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAbove-Ground Use Only: \u003c\/strong\u003eNewtonite Lath is restricted to non-earth-retaining walls. Do not use it where earth is retained on the opposite side or hydrostatic water pressure may occur.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDamp Diagnosis:\u003c\/strong\u003e The membrane separates finishes from damp masonry; it does not repair leaks, remove timber decay or correct every possible source of moisture in the building.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSecure Background Required: \u003c\/strong\u003eRemove unstable plaster and defective render, repair unsound material and select fixings capable of supporting the membrane and specified finish.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFinish-Specific Fixing Quantities:\u003c\/strong\u003e Use 16plugs\/m² for direct plaster or render and 10plugs\/m² for dot-and-dab plasterboard, adding local support where required by the background and detail layout.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSealed Butt Joints:\u003c\/strong\u003e Bring adjoining sheets together edge to edge and face-seal with Newton Mesh Tape. Do not substitute overlapping studded sheets or leave joints unsealed.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSealed Penetrations: \u003c\/strong\u003eApply Newtonite 801 Mastic at fixing holes and suitable service openings so dampness and salts cannot bridge to the room-facing finish.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFinishing Requirements:\u003c\/strong\u003e Follow the specified coat thicknesses, mix ratios, drying intervals and curing methods. Do not apply the recommended Whitewall plaster as a single coat.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFloor Bridging: \u003c\/strong\u003eKeep plaster and render 20-25mm above floor level, using a suitable finishing-profile or termination detail without introducing deliberate membrane-cavity ventilation.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Limits: \u003c\/strong\u003eDo not install fixings below -5°C or above +30°C. Separate tapes, mastics, adhesives and finishing products have their own application requirements.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFire And Protection:\u003c\/strong\u003e Euroclass E is the membrane's reaction-to-fire classification. The complete wall finish must satisfy the building requirements and protect the membrane throughout service.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGuarantee And Life Expectancy:\u003c\/strong\u003e The 30-year guarantee against deterioration and published life expectancy of at least 50 years apply to the membrane, subject to the applicable installation, protection and service conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eStorage And Shelf Life\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eStore rolls upright on end, under cover and away from direct sunlight. Protect them from crushing, sharp objects, contamination and conditions that could damage the mesh or distort the studded sheet.\u003c\/p\u003e\n\u003cp\u003eKeep Mesh Tape clean and dry and store Newtonite 801 Mastic, adhesives, treatments and finishing materials according to their own instructions. Check their shelf lives separately before use.\u003c\/p\u003e\n\u003cp\u003eThe membrane's published life expectancy concerns installed service, not a stated storage period for an unused roll. Inspect the membrane before fitting and do not use torn, heavily distorted or contaminated sections.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eOther Technical Information\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eNewtonite Lath is available in 1m x 10m, 1m x 20m, 1.2m x 10m and 2m x 20m rolls, providing nominal coverage of 10m², 20m², 12m² and 40m² respectively. Packaged membrane roll weights are 6.2kg, 11.34kg, 7.5kg and 24.6kg in the same order; these are not total kit weights.\u003c\/p\u003e\n\u003cp\u003eThe membrane has a unit weight of 505g\/m², a 0.5mm sheet thickness and a 3mm stud pattern. Thermal conductivity is 0.461W\/mK, the Sd value is above 604m and water-vapour resistance is above 3020MNs\/g. The Declaration of Performance records Euroclass E and compressive strength of 250kN.\u003c\/p\u003e\n\u003cp\u003eNewton's indicative finishing-material coverage is 1.6m² per 25kg bag of Whitewall plaster and 3.5m² per 25kg bag of NHL3.5 when mixed with sand at 1:2.5. Actual quantities depend on the specified thickness, background regularity and site waste.\u003c\/p\u003e\n\u003cp\u003eNewton guarantees the membrane against deterioration for 30 years and gives a published life expectancy of at least 50 years. Maintain the specified installation and protection conditions throughout service; these statements do not provide a combined guarantee for the wall, fixings, tapes or finishing materials.\u003cbr\u003e\u003c\/p\u003e\n\u003ch5\u003eFAQ's\u003c\/h5\u003e\n\u003ch3\u003eQ) What is the Newton Newtonite Lath Damp Proof Membrane Kit?\u003c\/h3\u003e\n\u003cp\u003eA) The Newton Newtonite Lath Damp Proof Membrane Kit combines a meshed HDPE membrane with Newtonite Mesh Plugs, Newtonite 801 Mastic Sealant and SDS Plus masonry drill bits. It provides the core materials for separating new internal finishes from dampness and salts within suitable above-ground walls. The membrane has raised 3mm studs and a heat-welded mesh face that provides a mechanical key for compatible plaster, render or plasterboard adhesive. Four nominal coverage options suit different refurbishment areas. The kit is intended for walls that do not retain earth, with jointing tape and finishing materials selected separately. Correct preparation, sealed details and suitable support remain essential to the completed wall construction.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eQ) What is included in each Newton Newtonite Lath Damp Proof Membrane Kit?\u003c\/h3\u003e\n\u003cp\u003eA) Every kit contains a Newtonite Lath membrane roll, 60mm Newtonite Mesh Plugs, Newtonite 801 Mastic Sealant and 8mm x 160mm SDS Plus drill bits. The 10m² kit supplies 160 plugs, two mastic cartridges and one drill bit. The 12m² kit supplies 200 plugs, two cartridges and one bit. The 20m² kit supplies 320 plugs, three cartridges and two bits. The 40m² kit supplies 650 plugs, four cartridges and two bits. These are fixed supply quantities rather than a guarantee that every detail is covered. Calculate any extra fixings or mastic from the actual installation. Newton Mesh Tape, finishing profiles, plaster, render, boards and adhesives are supplied separately.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eQ) Which Newtonite Lath kit size should I choose?\u003c\/h3\u003e\n\u003cp\u003eA) The 10m² kit contains a 1m x 10m roll, the 12m² kit a 1.2m x 10m roll, the 20m² kit a 1m x 20m roll and the 40m² kit a 2m x 20m roll. Measure the main walls, return walls, reveals and any other treated sections before choosing. Nominal coverage is the full uncut membrane area, so allow for trimming, awkward shapes and waste. Plan horizontal or vertical installation around wall height, openings and available access. Smaller rolls can simplify handling in restricted rooms, while wider sheets may reduce joint length. Also check the included fixing and mastic quantities against the selected finish and the actual support and sealing requirements.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eQ) What additional materials are needed with the Newtonite Lath kit?\u003c\/h3\u003e\n\u003cp\u003eA) Newton Mesh Tape is needed separately for sealing close butt joints and suitable repairs while maintaining a textured key for the finish. Measure the total joint length, corner cuts, reveals and detailing before ordering. Select the specified plaster, cement\/lime render, hydraulic lime or plasterboard system, including compatible adhesive and any required beads or finishing profiles. Preparation can also require suitable repair materials and separately specified damp or timber-decay treatments. Add Mesh Plugs or mastic if the actual layout needs more than the kit contains. The complete wall arrangement should be established before installation so supports, services, floor terminations and finishing materials work together without compromising the damp-proof separation.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eQ) How does the Newton Newtonite Lath Damp Proof Membrane Kit work?\u003c\/h3\u003e\n\u003cp\u003eA) Newtonite Lath is fixed with its studs towards the wall and the mesh facing into the room. The studs create channels for vapour equalisation between the sheet and background, while the HDPE separates the chosen finish from damp masonry and salts. Plaster, render or compatible adhesive engages with the mesh rather than bonding directly to the affected wall. The supplied plugs support the sheet, and Newtonite 801 Mastic seals their penetrations. Separately supplied Newton Mesh Tape seals adjoining sheets. The cavity does not need deliberate ventilation gaps at its top or bottom. Effective separation depends on continuous detailing around edges, services and floor junctions, together with the specified protective finish.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eQ) What are the advantages of buying Newtonite Lath as a kit?\u003c\/h3\u003e\n\u003cp\u003eA) The kit brings together the membrane, recommended masonry plugs, sealing mastic and suitable drill bits in defined quantities, simplifying ordering for measured refurbishment areas. The shallow stud profile helps retain usable room space, while the mesh permits suitable direct finishes without automatically requiring a framed lining. Mechanical fixing allows work over appropriately prepared damp masonry without waiting for the entire background to dry. Sound render can often remain after assessment, reducing unnecessary removal. Different roll widths and lengths accommodate access restrictions and wall layouts. Choosing a kit still requires accurate measurement and a finishing specification, because additional tape, local fixings, sealing materials and preparation products depend on the particular installation.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eQ) Where can the Newton Newtonite Lath Damp Proof Membrane Kit be used?\u003c\/h3\u003e\n\u003cp\u003eA) Suitable applications include the internal faces of above-ground masonry walls affected by dampness or residual salts. The kit can support localised repairs and larger refurbishments in domestic or commercial buildings where a compatible plaster, render or plasterboard finish is required. Typical projects include renewing salt-contaminated walls and protecting new finishes within an appropriately assessed rising-damp scheme. The wall must not retain earth, and its background must provide dependable support for the membrane and finish. Investigate moisture sources before enclosure and complete necessary remedial work. The kit protects the internal finish within its intended damp-proofing scope; it does not make an unsuitable structure sound or replace waterproofing designed for retained-ground conditions.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eQ) Can the Newtonite Lath kit be used for rising damp without a chemical DPC?\u003c\/h3\u003e\n\u003cp\u003eA) Newtonite Lath can form part of a suitable rising-damp refurbishment by separating the new finish from damp masonry and hygroscopic salts. A chemical DPC is not automatically required simply because the membrane is being fitted. Treatment should follow a proper diagnosis that considers wall construction, existing damp-proofing, ground levels, leaks and other moisture sources. Where a remedial DPC is specified, coordinate it with the membrane and floor junctions. Correct avoidable building defects wherever practical. The membrane does not itself dry the masonry, stop leaking pipework or treat timber decay. Its purpose is to protect the chosen internal finish, with underlying defects and any necessary remedial treatment addressed within the overall specification.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eQ) Is the Newton Newtonite Lath Damp Proof Membrane Kit suitable for basements?\u003c\/h3\u003e\n\u003cp\u003eA) Newtonite Lath is intended for above-ground walls that do not retain earth. It is unsuitable for a wall with retained ground on its opposite side, groundwater ingress or potential hydrostatic pressure. A basement retaining wall requires waterproofing selected for those conditions, including appropriate collection and discharge where a drained system is specified. The membrane's stud depth and material watertightness do not change this application limit. Establish external ground levels and the actual wall construction before ordering. Where a room is partly below ground or external levels vary along a wall, obtain a suitable design for the different areas and their junctions rather than extending this damp-proofing kit beyond its intended use.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eQ) Which substrates are suitable for the membrane and fixings supplied in the kit?\u003c\/h3\u003e\n\u003cp\u003eA) The supplied Newtonite Mesh Plugs are intended for suitable masonry backgrounds, including sound brickwork, blockwork, concrete and appropriate stone. Firmly bonded render can remain where the supporting construction provides dependable anchorage. Existing plaster should be removed because continuing dampness can soften it and weaken the fixing arrangement. Slightly friable mortar may need separately selected Newtonite Cob Plugs, provided the background can support the complete finish. Severely crumbling or structurally unsound areas must be repaired first. Suitable timber or plywood arrangements require the specified galvanised clout nails rather than the kit's masonry plugs. Assess the background, fixing grip and intended finish together before choosing the appropriate installation method.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eQ) How should walls be prepared before installing the Newtonite Lath kit?\u003c\/h3\u003e\n\u003cp\u003eA) Diagnose the moisture problem and assess the supporting wall before starting. Remove loose debris, organic matter, sharp projections, existing plaster and defective render. Retain sound render only where it remains firmly bonded and suitable for enclosure. Repair significant hollows, unstable masonry and unreliable fixing positions using appropriate materials. A reasonably flat background helps the membrane sit evenly and avoids excessively variable finishing thicknesses. Address leaks and other practical building defects, and have dry rot, wet rot or timber decay assessed and treated appropriately before covering. Locate concealed services before drilling. Allow repairs and treatments to reach the condition required by their instructions so they can safely support the membrane and selected finish.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eQ) What tools are required to install a Newtonite Lath Damp Proof Membrane Kit?\u003c\/h3\u003e\n\u003cp\u003eA) The kit supplies 8mm x 160mm SDS Plus masonry drill bits, while normal installation also requires a compatible drill, tape measure, marker, level, straightedge, sharp knife or shears, suitable wide-headed hammer or mallet, cleaning materials and a roller for pressing taped joints. Provide dust control and protective equipment appropriate to the substrate and work. Use a suitable cartridge gun for the supplied mastic and provide appropriate access equipment where needed. Have Newton Mesh Tape and the selected finishing materials ready before starting. Cut sheets on a clean surface and handle larger rolls with sufficient assistance. Check for hidden services and keep drilling debris away from joint surfaces and mastic seals.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eQ) How is the membrane in the Newtonite Lath kit fitted to a wall?\u003c\/h3\u003e\n\u003cp\u003eA) Plan the sheet layout around wall height, openings, corners and access, choosing horizontal or vertical fitting as appropriate. Position the studs against the wall with the mesh facing the room. Align the first section accurately and hold it taut and square while fitting the initial plugs. Apply Newtonite 801 Mastic around each fixing hole before driving the plug home, then complete the support pattern required by the finish. Avoid sagging, bulging or excessive tension. Bring adjoining edges together as close butt joints and seal them with Newton Mesh Tape. Complete returns, reveals, service openings and floor details before inspection. The membrane must remain stable and fully sealed before plaster, render or adhesive is applied.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eQ) What drill diameter and depth should be used for the kit's Newtonite Mesh Plugs?\u003c\/h3\u003e\n\u003cp\u003eA) Use the supplied 8mm SDS Plus masonry bit for the recommended 60mm Newtonite Mesh Plugs. Drill through the membrane into the wall to a depth of at least 60mm, allowing additional clearance for debris so the plug seats fully. Apply Newtonite 801 Mastic around the hole before driving the plug home squarely with a suitable hammer or mallet. Check that the fixing grips securely and that the penetration remains sealed without leaving the sheet distorted or loose. Other plug types or lengths require their own specified drilling arrangement. Do not install membrane fixings below -5°C or above +30°C, and observe the separate application limits of the mastic and other products.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eQ) Are the included plugs sufficient, and how closely should they be spaced?\u003c\/h3\u003e\n\u003cp\u003eA) Direct plaster or render requires 16plugs\/m², with fixing centres no greater than 250mm. Dot-and-dab plasterboard requires 10plugs\/m², distributed to support the membrane and coordinate with the board arrangement. The kits supply 160, 200, 320 or 650 plugs for their respective nominal areas, but actual requirements depend on cuts, corners, edges, openings and background condition. Additional local support may therefore be necessary. Calculate the layout before installation instead of assuming a fixed kit quantity covers every detail. Each plug must obtain dependable grip and have a sealed penetration. Correct loose fixings or weak backing areas before finishing so the sheet cannot sag, bulge or move beneath the chosen wall surface.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eQ) How are Newtonite Lath joints sealed, and is jointing tape included?\u003c\/h3\u003e\n\u003cp\u003eA) Newton Mesh Tape is supplied separately and is required for the standard close butt joints between sheets. Bring edges together without overlapping the studded membrane or leaving open gaps. Clean and dry the mesh face, then centre the tape over the seam so approximately equal widths adhere to each sheet. Remove the release liner progressively and press firmly across the entire tape width, eliminating wrinkles and loose edges. The textured face maintains a key for plaster or render across the connection. Suitable gentle warming can assist in cold or damp conditions, but avoid overheating the membrane. Inspect every joint and replace contaminated or poorly bonded tape before applying the finish.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eQ) How should the Newtonite Lath kit be detailed around corners and reveals?\u003c\/h3\u003e\n\u003cp\u003eA) Continue the membrane around corners where it forms neatly without distortion, maintaining the studs against the wall and the mesh towards the room. At difficult angles, cut at a controlled position, form a close butt joint and seal with Newton Mesh Tape. Keep edges adequately supported so they cannot move beneath the finish. Extend the membrane 300mm onto return walls to protect adjoining finishes from dampness passing around the treated area. Continue into reveals where required, coordinating frames, membrane edges and the finishing system. Avoid loose folds and excessively variable plaster thickness. Include these additional areas when choosing the kit size, and inspect each perimeter detail before the membrane becomes concealed.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eQ) How should pipes, sockets and heavy wall fittings be installed with Newtonite Lath?\u003c\/h3\u003e\n\u003cp\u003eA) Plan services and fixtures before installing the membrane, keeping penetrations to a minimum. Cut closely around necessary pipes and protrusions, then apply Newtonite 801 Mastic continuously around the opening to preserve damp-proof separation. Where brackets require bolts through the sheet, introduce the mastic before inserting the fixings and ensure the anchors engage securely with the structural background. Radiators, cupboards and shelving need suitable independent support; the membrane mesh and plaster do not carry these loads by themselves. Coordinate electrical boxes and cable routes with the finished wall construction. Later alterations require the same sealed detailing, because an unsealed fixing or oversized opening can allow dampness and salts to reach the new surface.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eQ) What floor clearance is required for plaster or render over the kit membrane?\u003c\/h3\u003e\n\u003cp\u003eA) Keep plaster and render 20–25mm above floor level to prevent moisture bridging from the floor into the wall finish. Where suitable, fit a separately supplied Newtonite Finishing Profile at the same time as the membrane. The profile comes in 2m lengths and acts as a plaster stop. It is unsuitable where the wall run is uneven or the membrane continues below the slab, so those situations require an appropriate alternative termination. Once the finish is thoroughly dry, timber skirting can cover the clearance. This raised plaster or render edge is distinct from the membrane termination. It does not mean the cavity behind Newtonite Lath should be deliberately opened for ventilation.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eQ) Can the Newtonite Lath kit be used where a new floor slab is being laid?\u003c\/h3\u003e\n\u003cp\u003eA) Where a new slab forms part of an above-ground refurbishment, fit Newtonite Lath before the slab is laid and arrange the floor damp-proof membrane to extend upwards in front of the wall membrane. Coordinate this connection with slab depth, insulation, finished floor level and the raised plaster or render edge before concrete placement. The detail must maintain damp-proof continuity and prevent floor moisture bridging into the finished wall. Protect the membrane during pouring and later work, and inspect the connection before it is concealed. Floor DPM, insulation and slab materials are separate from the kit. This above-ground junction does not extend Newtonite Lath's suitability to earth-retaining walls or groundwater waterproofing.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eQ) Which plaster can be applied to the Newtonite Lath membrane supplied with the kit?\u003c\/h3\u003e\n\u003cp\u003eA) Tarmac Whitewall One Coat Plaster is the recommended option, applied over Newtonite Lath in two separate coats. Use a 6mm scratch coat followed by a 6mm second or float coat, allowing at least 24 hours between coats. An optional 3mm finishing coat can provide the final surface. Work the material firmly into the mesh and follow its mixing, application and environmental requirements. Despite its name, this plaster should not be applied as a single coat over the membrane. Check fixing stability, mastic seals and taped joints before starting, maintain the specified floor clearance and allow the finish to dry thoroughly before decorating. Plaster and associated finishing products are supplied separately.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eQ) How is cement\/lime render applied over Newtonite Lath?\u003c\/h3\u003e\n\u003cp\u003eA) The specified traditional render uses two 7mm coats, giving 14mm total thickness. The scratch coat contains one part lime, one part cement and five parts clean, well-graded sharp sand. The float coat uses one part lime, one part cement and six parts sand. Work the first coat thoroughly into the mesh and allow each coat at least seven days, preferably ten days or longer where possible, with suitable curing before continuing. Confirm that the scratch coat is firm behind the mesh as well as at the surface. Dampen it before applying the second coat and protect against rapid drying. A smooth render finish is not recommended; any optional finishing skim requires fully cured render.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eQ) Can natural hydraulic lime be used over the Newtonite Lath kit membrane?\u003c\/h3\u003e\n\u003cp\u003eA) Newtonite Lath can receive the specified NHL3.5 system using 2.5 parts suitable sand to one part NHL3.5, mixed in accordance with the material instructions. Apply a 10mm scratch coat and a 10mm second or float coat, giving 20mm combined thickness. Push the initial coat firmly into the mesh and scratch its surface without damaging the mesh. Check the next day and rub out cracks as required. Leave the scratch coat to set for at least seven days, protected from draughts and temperature extremes. Confirm that material behind the mesh has hardened, dampen the backing appropriately and apply the second coat. Continue the specified protection and tending throughout curing.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eQ) Can plasterboard or insulated plasterboard be bonded to Newtonite Lath?\u003c\/h3\u003e\n\u003cp\u003eA) Suitable plasterboard can be bonded with a compatible proprietary adhesive, placing dabs on plug heads, board edges and the membrane mesh. Provide 50% adhesive coverage over the membrane surface and coordinate the board layout with the 10plugs\/m² support arrangement. Follow the board and adhesive requirements for setting, jointing and decoration. Laminated or insulated boards require additional mechanical restraint, including a fixing at each side within the upper half of the board. Position these above the membrane height or, where penetrating the sheet, above the anticipated moisture level in accordance with the designed detail. The complete construction must satisfy the applicable fire requirements. Boards, adhesive and additional restraints are supplied separately.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eQ) Does the Newtonite Lath kit require curing before the wall can be decorated?\u003c\/h3\u003e\n\u003cp\u003eA) The prefabricated membrane itself has no wet-curing period, but repairs, mastic, adhesive, plaster and render each have their own setting, curing and drying requirements. Begin finishing only when the membrane is stable and every joint and penetration is properly sealed. Cement\/lime and hydraulic lime finishes need controlled curing, with protection from draughts, sunlight, direct heat and excessive dehumidification. Dampen and protect them as specified. Curing develops binder strength, while drying prepares the finish for decoration; these are separate stages. Do not apply paint or other decorations until plaster or render is thoroughly dry. Choose a coating suitable for the finish and room conditions, and maintain appropriate normal ventilation and heating.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eQ) Does Newtonite Lath prevent condensation, and should its cavity be ventilated?\u003c\/h3\u003e\n\u003cp\u003eA) Newtonite Lath separates finishes from dampness within the wall, but it does not remove moisture generated inside the room. Cooking, bathing, clothes drying and normal occupation still require suitable ventilation, heating and humidity control. Insulated wall constructions also need appropriate condensation assessment because the membrane has high resistance to vapour movement. Its studded channels allow vapour equalisation without deliberately ventilated openings at the top or bottom. Do not create such openings as a substitute for room ventilation or confuse them with the required plaster clearance above the floor. Investigate persistent mould, staining or condensation and address the responsible environmental or building defect rather than simply decorating over the affected surface.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eQ) What are the main technical specifications of the membrane in the Newtonite Lath kit?\u003c\/h3\u003e\n\u003cp\u003eA) Newtonite Lath has a 0.5mm HDPE sheet, raised 3mm studs and a unit weight of 505g\/m². Thermal conductivity is 0.461W\/mK and water-vapour diffusion resistance has an Sd value above 604m. The service-temperature range is -50°C to +80°C, while fixing installation is limited to -5°C to +30°C. The membrane is declared as a Type V damp-proof sheet to BS EN 13967:2012+A1:2017 and has a Euroclass E reaction-to-fire classification. These characteristics apply to the membrane rather than every kit component. The complete wall construction needs its own suitable protective finish and fire specification. Material performance figures do not extend the membrane's scope to groundwater ingress or earth-retaining walls.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eQ) How long should the Newtonite Lath membrane last, and what guarantee applies to the kit?\u003c\/h3\u003e\n\u003cp\u003eA) Newton guarantees the Newtonite Lath membrane against deterioration for 30 years and gives it a life expectancy of at least 50 years, subject to correct installation, protection and service conditions. These statements apply to the membrane itself and do not create a combined guarantee for the kit, fixings, mastic, tapes or finished wall. Long-term performance depends on suitable preparation, secure support, sealed details and a protective finish that remains sound. Address new leaks and avoid uncontrolled later drilling. Store unused rolls upright under cover, protected from sunlight, crushing, contamination and sharp objects. Keep accessories within their own storage and shelf-life requirements, and inspect all materials before incorporating them into the work.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eQ) What inspection, maintenance and repairs does a Newtonite Lath installation need?\u003c\/h3\u003e\n\u003cp\u003eA) Before finishing, inspect the complete installation for secure plugs, effective mastic seals, close butt joints and fully bonded Newton Mesh Tape. Check corners, 300mm returns, reveals, service openings and floor connections for routes that could bridge dampness into the finish. Repair suitable local damage with compatible membrane and Mesh Tape details, restoring both the seal and keyed surface. Replace sections where a dependable repair cannot be formed. The protected membrane normally needs little direct attention, but new staining, cracking or dampness should be investigated. Explain the wall construction to later trades so service alterations and heavy fixtures use planned, sealed fixing arrangements. Retain photographs of concealed details for future reference.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eQ) What limitations and practical tips should I understand before installing a Newtonite Lath kit?\u003c\/h3\u003e\n\u003cp\u003eA) Use the kit only for suitable above-ground walls that do not retain earth. It does not repair structural defects, remove timber decay or replace treatment of avoidable moisture sources. Choose the finish before installation, calculate the actual fixing and sealing requirements and order Newton Mesh Tape separately. Prepare a firm, reasonably flat background, keep contact surfaces clean and dry and seal every penetration. Maintain stable support without sagging, preserve the specified floor clearance and follow finishing thicknesses and curing times. Inspect and photograph the installation before concealment. Protect it from later punctures and give occupants clear information about the membrane, approved fixing arrangements and the need to investigate future dampness promptly.\u003cbr\u003e\u003c\/p\u003e\n\u003ch5\u003eData Sheets\u003c\/h5\u003e\n\u003ch3\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2617\/5036\/files\/NEWTON_NEWTONITE_LATH_TECH.pdf?v=1793881304\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003eTechnical Data Sheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/h3\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2617\/5036\/files\/NEWTON_NEWTONITE_LATH_TECH.pdf?v=1793881304\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2617\/5036\/files\/NEWTONITE_LATH_TECH_160x160.jpg?v=1793881234\" alt=\"\" style=\"float: none;\"\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003cp style=\"text-align: start;\"\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: start;\"\u003e \u003c\/p\u003e\n\u003ch3 style=\"text-align: start;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2617\/5036\/files\/NEWTON_NEWTONITE_LATH_DOP.pdf?v=1793881308\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003eDeclaration of Performance (DoP)\u003c\/strong\u003e\u003c\/a\u003e\u003c\/h3\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2617\/5036\/files\/NEWTON_NEWTONITE_LATH_DOP.pdf?v=1793881308\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2617\/5036\/files\/NEWTONITE_LATH_DOP_160x160.jpg?v=1793881234\" alt=\"\" style=\"float: none;\"\u003e\u003c\/a\u003e\u003c\/div\u003e","brand":"John Newton \u0026 Co. Ltd","offers":[{"title":"10M² Kit - (W) 1.0M x (L) 10M Roll","offer_id":28295739375715,"sku":"NM16K1M","price":104.75,"currency_code":"GBP","in_stock":true},{"title":"20M² Kit - (W) 1.0M x (L) 20M Roll","offer_id":28312231936099,"sku":"NM21K1M","price":179.3,"currency_code":"GBP","in_stock":true},{"title":"12M² Kit - (W) 1.2M x (L) 10M Roll","offer_id":60359917175168,"sku":"NM9K1M","price":115.85,"currency_code":"GBP","in_stock":true},{"title":"40M² Kit - (W) 2.0M x (L) 20M Roll","offer_id":28312234819683,"sku":"NM22K1M","price":325.4,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2617\/5036\/files\/newton-newtonite-lath-damp-proof-membrane-kit-with-fixings-sealing-mastic-10m-w-1-0m-x-l-roll-880.webp?v=1794320707","url":"https:\/\/www.platinumchemicals.co.uk\/products\/newton-newtonite-lath-meshed-damp-proof-membrane-kit","provider":"Platinum Chemicals","version":"1.0","type":"link"}