Beeswift A1 Gas Filter Cartridges (For Organic Vapour Hazards)

Beeswift A1 Gas Filter Cartridges are essential accessories for the Beeswift Twin Filter Face Mask (sold separately). Designed to protect against organic vapour hazards, such as solvents, these cartridges offer reliable and efficient filtration.

With a maximum use level of 1000ppm or 10 times the Occupational Exposure Limit (OEL), they provide the assurance of optimal safety in various working environments. Sold in pairs, these cartridges guarantee extended use and peace of mind.

Unit

Unit
Sale price £5.25 Regular price £6.50
ex. VAT
Regular price £6.30 £6.30 Sale price Regular price £7.80
inc. VAT

Beeswift A1 Gas Filter Cartridges are essential accessories for the Beeswift Twin Filter Face Mask (sold separately). Designed to protect against organic vapour hazards, such as solvents, these cartridges offer reliable and efficient filtration.

With a maximum use level of 1000ppm or 10 times the Occupational Exposure Limit (OEL), they provide the assurance of optimal safety in various working environments. Sold in pairs, these cartridges guarantee extended use and peace of mind.

Free Delivery

on orders over £100
(ex. VAT, mainland UK only)

Free Help & Advice

Call 01355 222 777
Mon.-Fri 8:30am - 4:15pm, or email us

Next Day Delivery

Order Before 2:30pm for Same Day Despatch (terms apply)

Great Service

A proudly independent family business with 40 years experience

Beeswift A1 Gas Filter Cartridges

Beeswift A1 Gas Filter Cartridges are meticulously engineered to provide exceptional protection against organic vapour hazards. Designed to be used with the Beeswift Twin Filter Face Mask (sold separately), these cartridges form a vital part of a comprehensive respiratory protection system.

These gas filter cartridges are specifically designed for protecting against organic vapours, including solvents like White Spirit, Toluene, and Carbon Tetrachloride (CC14). With their efficient filtration capabilities, they ensure users are shielded from harmful substances commonly encountered in various industries.

The Beeswift A1 Gas Filter Cartridges have a maximum use level of 1000ppm or 10 times the Occupational Exposure Limit (OEL), whichever is lower. This ensures optimal safety and compliance with industry regulations. These cartridges are essential in reducing the inhalation of hazardous vapours to safe levels, minimising potential health risks.

Each pack contains two cartridges, allowing for extended use and easy replacement when necessary. The durable construction ensures long-lasting performance, making them a cost-effective choice for respiratory protection.


Product Benefits:

  • Efficient Filtration: The Beeswift A1 Gas Filter Cartridges efficiently filter out organic vapours, such as solvents, providing a high level of protection. With their advanced filtration technology, they reduce the inhalation of harmful substances to safe levels, ensuring the well-being of users.

  • Reliable Safety: These cartridges have a maximum use level of 1000ppm or 10 times the Occupational Exposure Limit (OEL), whichever is lower. This ensures compliance with industry safety standards and regulations, safeguarding the health of workers in various environments.

  • Extended Use: Supplied in pairs, these cartridges offer extended use and value for money. Users can rely on their enduring performance, knowing they are protected against organic vapour hazards for an extended period.

  • Easy Replacement: The twin cartridge design allows for quick and hassle-free replacement when required. Users can easily remove the spent cartridges and install new ones, ensuring continued protection without interruption.

  • Cost-Effective Solution: As an integral part of respiratory protection, Beeswift A1 Gas Filter Cartridges offer a cost-effective solution. Their durable construction ensures long-lasting performance, reducing the need for frequent replacements and ultimately minimising overall costs.


Typical Applications:

  • Automotive Workshops: Beeswift A1 Gas Filter Cartridges are ideal for automotive workshops where organic solvents are commonly used. They protect workers from inhaling harmful vapours released during car repair and maintenance activities.

  • Paint and Coating Application: In industries involving paint and coating applications, these cartridges are essential in safeguarding workers. They effectively filter organic vapours, ensuring a safe working environment.

  • Construction: Construction professionals working with solvents and other organic materials benefit from the reliable protection offered by these cartridges. They reduce the inhalation of harmful substances, promoting a healthy and safe workplace.

  • Pharmaceutical and Chemical Manufacturing: Workers in pharmaceutical and chemical manufacturing plants are exposed to organic vapours. Beeswift A1 Gas Filter Cartridges provide a vital safety measure, protecting against potential health risks in these environments.

  • Printing Industry: Workers in Printing Industries working with inks and solvents can rely on the high-performance filtration capabilities of these cartridges. They effectively remove organic vapours, ensuring the well-being of workers.

Q) What are Beeswift A1 Gas Filter Cartridges designed for?

A) Beeswift A1 Gas Filter Cartridges are specifically designed to protect against organic vapour hazards, such as those emanating from solvents including White Spirit, Toluene, and Carbon Tetrachloride (CC14). When used with the Beeswift Twin Filter Face Mask, these cartridges provide efficient filtration, reducing the inhalation of harmful organic vapours to safe levels. Their construction ensures reliable safety and compliance with industry standards, making them essential for various working environments where organic vapours are present.


Q) How do Beeswift A1 Gas Filter Cartridges work?

A) The cartridges work by trapping organic vapour molecules through adsorption onto the surface of the activated carbon within the filter. This process is facilitated by the large surface area of the carbon granules, which binds the vapour molecules, effectively removing them from the air being inhaled through the mask. The advanced filtration technology ensures that the air reaching the user's respiratory system is clean and free from hazardous organic vapours, providing a high level of protection in environments with potential chemical exposure.


Q) What is the maximum use level of Beeswift A1 Gas Filter Cartridges, and why is it important?

A) The maximum use level of Beeswift A1 Gas Filter Cartridges is set at 1000ppm (parts per million) or 10 times the Occupational Exposure Limit (OEL), whichever is lower. This benchmark is crucial as it determines the highest concentration of organic vapours from which the cartridges can protect the user. Adhering to this limit ensures that workers are shielded from concentrations of organic vapours that exceed safety thresholds, maintaining optimal safety and compliance with industry regulations.


Q) Where are Beeswift A1 Gas Filter Cartridges typically used?

A) These cartridges are typically used in environments where workers are exposed to organic vapours, such as automotive workshops, paint and coating applications, construction sites, pharmaceutical and chemical manufacturing facilities, and the printing industry. They are essential for professionals who work with solvents and other organic materials, providing necessary respiratory protection against harmful vapours.


Q) How often should Beeswift A1 Gas Filter Cartridges be replaced?

A) Replacement frequency depends on several factors, including the level of vapour exposure and the duration of use. Cartridges should be replaced when the user begins to smell or taste the vapours, indicating that the filter capacity is exhausted, or according to the manufacturer's recommended schedule. Regular inspection for signs of damage or saturation is also essential to maintain effective protection.


Q) Can Beeswift A1 Gas Filter Cartridges filter out other types of hazards?

A) While Beeswift A1 Gas Filter Cartridges are primarily designed for protection against organic vapours, they are not suitable for filtering particulates, inorganic gases, or other types of chemical hazards. For comprehensive protection in environments with multiple types of hazards, users may need to employ additional types of filter cartridges or a different respiratory protection system designed to address those specific needs.


Q) How do I install Beeswift A1 Gas Filter Cartridges onto the Twin Filter Face Mask?

A) Installing Beeswift A1 Gas Filter Cartridges onto the Twin Filter Face Mask is straightforward. Simply align the cartridges with the mask's connection points and twist them into place until secure. This ensures a tight seal and prevents leakage, allowing the filtration system to function effectively. The easy replacement feature allows users to quickly change cartridges as needed, minimising downtime in the workplace.


Q) What are the advantages of using Beeswift A1 Gas Filter Cartridges?

A) The primary advantages include efficient filtration of organic vapours, reliable safety compliance with industry standards, extended use due to durability, and cost-effectiveness through long-lasting performance. Additionally, the ease of cartridge replacement enhances user convenience, ensuring continuous protection against hazardous vapours without significant interruptions to work activities.


Q) Are there any specific maintenance or storage recommendations for Beeswift A1 Gas Filter Cartridges?

A) To ensure optimal performance and longevity, Beeswift A1 Gas Filter Cartridges should be stored in a cool, dry place away from direct sunlight and organic vapours. They should remain in their original packaging until use to prevent premature saturation. Regularly inspect the cartridges for damage or wear and replace them as necessary. Proper maintenance and storage practices help maintain the cartridges' filtration capabilities and ensure they are ready for use when needed.


Q) How do I determine if Beeswift A1 Gas Filter Cartridges are the right choice for my work environment?

A) Determining the suitability of Beeswift A1 Gas Filter Cartridges for your work environment involves assessing the specific hazards present. If organic vapours from solvents are a primary concern, these cartridges offer the necessary protection required to maintain a safe breathing environment. Evaluate the types of chemicals used in your workplace and their concentrations to ensure they fall within the cartridges' protective capabilities. It's also crucial to consider the Occupational Exposure Limits (OEL) for the substances you're exposed to and compare them with the maximum use level of the cartridges. Consulting safety data sheets (SDS) for the chemicals in use can provide valuable information on the necessary level of respiratory protection. If your assessment reveals a significant presence of organic vapours at levels that the Beeswift A1 Gas Filter Cartridges are designed to protect against, then they are likely a suitable choice for ensuring your safety and compliance with industry regulations in your work environment.

Beeswift A1 Gas Filter Cartridges

Beeswift A1 Gas Filter Cartridges are meticulously engineered to provide exceptional protection against organic vapour hazards. Designed to be used with the Beeswift Twin Filter Face Mask (sold separately), these cartridges form a vital part of a comprehensive respiratory protection system.

These gas filter cartridges are specifically designed for protecting against organic vapours, including solvents like White Spirit, Toluene, and Carbon Tetrachloride (CC14). With their efficient filtration capabilities, they ensure users are shielded from harmful substances commonly encountered in various industries.

The Beeswift A1 Gas Filter Cartridges have a maximum use level of 1000ppm or 10 times the Occupational Exposure Limit (OEL), whichever is lower. This ensures optimal safety and compliance with industry regulations. These cartridges are essential in reducing the inhalation of hazardous vapours to safe levels, minimising potential health risks.

Each pack contains two cartridges, allowing for extended use and easy replacement when necessary. The durable construction ensures long-lasting performance, making them a cost-effective choice for respiratory protection.


Product Benefits:

  • Efficient Filtration: The Beeswift A1 Gas Filter Cartridges efficiently filter out organic vapours, such as solvents, providing a high level of protection. With their advanced filtration technology, they reduce the inhalation of harmful substances to safe levels, ensuring the well-being of users.

  • Reliable Safety: These cartridges have a maximum use level of 1000ppm or 10 times the Occupational Exposure Limit (OEL), whichever is lower. This ensures compliance with industry safety standards and regulations, safeguarding the health of workers in various environments.

  • Extended Use: Supplied in pairs, these cartridges offer extended use and value for money. Users can rely on their enduring performance, knowing they are protected against organic vapour hazards for an extended period.

  • Easy Replacement: The twin cartridge design allows for quick and hassle-free replacement when required. Users can easily remove the spent cartridges and install new ones, ensuring continued protection without interruption.

  • Cost-Effective Solution: As an integral part of respiratory protection, Beeswift A1 Gas Filter Cartridges offer a cost-effective solution. Their durable construction ensures long-lasting performance, reducing the need for frequent replacements and ultimately minimising overall costs.


Typical Applications:

  • Automotive Workshops: Beeswift A1 Gas Filter Cartridges are ideal for automotive workshops where organic solvents are commonly used. They protect workers from inhaling harmful vapours released during car repair and maintenance activities.

  • Paint and Coating Application: In industries involving paint and coating applications, these cartridges are essential in safeguarding workers. They effectively filter organic vapours, ensuring a safe working environment.

  • Construction: Construction professionals working with solvents and other organic materials benefit from the reliable protection offered by these cartridges. They reduce the inhalation of harmful substances, promoting a healthy and safe workplace.

  • Pharmaceutical and Chemical Manufacturing: Workers in pharmaceutical and chemical manufacturing plants are exposed to organic vapours. Beeswift A1 Gas Filter Cartridges provide a vital safety measure, protecting against potential health risks in these environments.

  • Printing Industry: Workers in Printing Industries working with inks and solvents can rely on the high-performance filtration capabilities of these cartridges. They effectively remove organic vapours, ensuring the well-being of workers.

Q) What are Beeswift A1 Gas Filter Cartridges designed for?

A) Beeswift A1 Gas Filter Cartridges are specifically designed to protect against organic vapour hazards, such as those emanating from solvents including White Spirit, Toluene, and Carbon Tetrachloride (CC14). When used with the Beeswift Twin Filter Face Mask, these cartridges provide efficient filtration, reducing the inhalation of harmful organic vapours to safe levels. Their construction ensures reliable safety and compliance with industry standards, making them essential for various working environments where organic vapours are present.


Q) How do Beeswift A1 Gas Filter Cartridges work?

A) The cartridges work by trapping organic vapour molecules through adsorption onto the surface of the activated carbon within the filter. This process is facilitated by the large surface area of the carbon granules, which binds the vapour molecules, effectively removing them from the air being inhaled through the mask. The advanced filtration technology ensures that the air reaching the user's respiratory system is clean and free from hazardous organic vapours, providing a high level of protection in environments with potential chemical exposure.


Q) What is the maximum use level of Beeswift A1 Gas Filter Cartridges, and why is it important?

A) The maximum use level of Beeswift A1 Gas Filter Cartridges is set at 1000ppm (parts per million) or 10 times the Occupational Exposure Limit (OEL), whichever is lower. This benchmark is crucial as it determines the highest concentration of organic vapours from which the cartridges can protect the user. Adhering to this limit ensures that workers are shielded from concentrations of organic vapours that exceed safety thresholds, maintaining optimal safety and compliance with industry regulations.


Q) Where are Beeswift A1 Gas Filter Cartridges typically used?

A) These cartridges are typically used in environments where workers are exposed to organic vapours, such as automotive workshops, paint and coating applications, construction sites, pharmaceutical and chemical manufacturing facilities, and the printing industry. They are essential for professionals who work with solvents and other organic materials, providing necessary respiratory protection against harmful vapours.


Q) How often should Beeswift A1 Gas Filter Cartridges be replaced?

A) Replacement frequency depends on several factors, including the level of vapour exposure and the duration of use. Cartridges should be replaced when the user begins to smell or taste the vapours, indicating that the filter capacity is exhausted, or according to the manufacturer's recommended schedule. Regular inspection for signs of damage or saturation is also essential to maintain effective protection.


Q) Can Beeswift A1 Gas Filter Cartridges filter out other types of hazards?

A) While Beeswift A1 Gas Filter Cartridges are primarily designed for protection against organic vapours, they are not suitable for filtering particulates, inorganic gases, or other types of chemical hazards. For comprehensive protection in environments with multiple types of hazards, users may need to employ additional types of filter cartridges or a different respiratory protection system designed to address those specific needs.


Q) How do I install Beeswift A1 Gas Filter Cartridges onto the Twin Filter Face Mask?

A) Installing Beeswift A1 Gas Filter Cartridges onto the Twin Filter Face Mask is straightforward. Simply align the cartridges with the mask's connection points and twist them into place until secure. This ensures a tight seal and prevents leakage, allowing the filtration system to function effectively. The easy replacement feature allows users to quickly change cartridges as needed, minimising downtime in the workplace.


Q) What are the advantages of using Beeswift A1 Gas Filter Cartridges?

A) The primary advantages include efficient filtration of organic vapours, reliable safety compliance with industry standards, extended use due to durability, and cost-effectiveness through long-lasting performance. Additionally, the ease of cartridge replacement enhances user convenience, ensuring continuous protection against hazardous vapours without significant interruptions to work activities.


Q) Are there any specific maintenance or storage recommendations for Beeswift A1 Gas Filter Cartridges?

A) To ensure optimal performance and longevity, Beeswift A1 Gas Filter Cartridges should be stored in a cool, dry place away from direct sunlight and organic vapours. They should remain in their original packaging until use to prevent premature saturation. Regularly inspect the cartridges for damage or wear and replace them as necessary. Proper maintenance and storage practices help maintain the cartridges' filtration capabilities and ensure they are ready for use when needed.


Q) How do I determine if Beeswift A1 Gas Filter Cartridges are the right choice for my work environment?

A) Determining the suitability of Beeswift A1 Gas Filter Cartridges for your work environment involves assessing the specific hazards present. If organic vapours from solvents are a primary concern, these cartridges offer the necessary protection required to maintain a safe breathing environment. Evaluate the types of chemicals used in your workplace and their concentrations to ensure they fall within the cartridges' protective capabilities. It's also crucial to consider the Occupational Exposure Limits (OEL) for the substances you're exposed to and compare them with the maximum use level of the cartridges. Consulting safety data sheets (SDS) for the chemicals in use can provide valuable information on the necessary level of respiratory protection. If your assessment reveals a significant presence of organic vapours at levels that the Beeswift A1 Gas Filter Cartridges are designed to protect against, then they are likely a suitable choice for ensuring your safety and compliance with industry regulations in your work environment.

You Might Also Like

On Sale
On Sale
On Sale
On Sale